[RHOCP 4] Prometheus target 'serviceMonitor/openshift-metallb-system/monitor-metallb-controller/0' has a error message 'server returned HTTP status 502 Bad Gateway'
Issue
-
Default
Metallb Operatorsetup has no issue andPrometheus targetfor theControllerisUp. The issue is observed when trying to host thespeakeron specific infra nodes,speakerpods are scheduled on theinfra nodeswith the specific taints applied, butPrometheus targethas a failure with below error:server returned HTTP status 502 Bad Gateway -
kube-rbac-proxycontainer in the metallbcontrollerpod shows the below error:$ oc logs controller-xxxx -c kube-rbac-proxy -n metallb-system http: proxy error: dial tcp 10.xx.xx.xx:7472: connect: connection refused
Environment
- Red Hat OpenShift Container Platform (RHOCP)