Storage LUN path does not recover during FC cable pull test with QLogic QLE2672 adapter
Issue
-
While testing FC cable pull test on
RHEL 7.5
withQLogic QLE2672
adapter, it was found that once FC cable is reconnected, the failed SAN devices are unable to recover automatically.- The issue is intermittent in nature and occurs with
QLE2672
HBA firmware version8.03.01
. - The same issue was not reproducible while using
QLE2672
HBA with firmware version7.01.00
.
Following fw errors were logged during FC cable pull test:
kernel: qla2xxx [0000:06:00.0]-5003:0: ISP System Error - mbx1=ae45h mbx2=10h mbx3=1h mbx7=0h. kernel: qla2xxx [0000:06:00.0]-d001:0: Firmware dump saved to temp buffer (0/ffffaa1386b54000), dump status flags (0x3f). kernel: qla2xxx [0000:06:00.0]-00af:0: Performing ISP error recovery - ha=ffff972d53b2a000. kernel: qla2xxx [0000:06:00.0]-0075:0: ZIO mode 6 enabled; timer delay (200 us). kernel: qla2xxx [0000:06:00.0]-1005:0: Cmd 0x3e aborted with timeout since ISP Abort is pending kernel: qla2xxx [0000:06:00.0]-00ce:0: Unsupported FAC firmware (8.03.01). kernel: qla2xxx [0000:06:00.0]-500a:0: LOOP UP detected (16 Gbps).
- The issue is intermittent in nature and occurs with
Environment
- Red Hat Enterprise Linux 7.5
QLE2672
HBA firmware version8.03.01
Subscriber exclusive content