Storage LUN path does not recover during FC cable pull test with QLogic QLE2672 adapter

Solution Verified - Updated -

Issue

  • While testing FC cable pull test on RHEL 7.5 with QLogic QLE2672 adapter, it was found that once FC cable is reconnected, the failed SAN devices are unable to recover automatically.

    • The issue is intermittent in nature and occurs with QLE2672 HBA firmware version 8.03.01.
    • The same issue was not reproducible while using QLE2672 HBA with firmware version 7.01.00.

    Following fw errors were logged during FC cable pull test:

    kernel: qla2xxx [0000:06:00.0]-5003:0: ISP System Error - mbx1=ae45h mbx2=10h mbx3=1h mbx7=0h.
    kernel: qla2xxx [0000:06:00.0]-d001:0: Firmware dump saved to temp buffer (0/ffffaa1386b54000), dump status flags (0x3f).
    kernel: qla2xxx [0000:06:00.0]-00af:0: Performing ISP error recovery - ha=ffff972d53b2a000.
    kernel: qla2xxx [0000:06:00.0]-0075:0: ZIO mode 6 enabled; timer delay (200 us).
    kernel: qla2xxx [0000:06:00.0]-1005:0: Cmd 0x3e aborted with timeout since ISP Abort is pending
    kernel: qla2xxx [0000:06:00.0]-00ce:0: Unsupported FAC firmware (8.03.01).
    kernel: qla2xxx [0000:06:00.0]-500a:0: LOOP UP detected (16 Gbps).
    

Environment

  • Red Hat Enterprise Linux 7.5
  • QLE2672 HBA firmware version 8.03.01