Redundancy behavior of gluster replicated-distributed volume
Issue
-
Need confirmation about the client access behavior when multiple gluster node down.
-
Architecture
4 nodes gluster running replicated-distributed volumeN1 replicate to N2
N3 replcate to N4
N1/N3 distribute
N2/N4 distribute -
Client access behavior
- Shutdown any one node -> No impact
- Shutdown N1 and N3 -> No impact to fuse access from client
- Shutdown N2 and N4 -> No impact to fuse access from client
- Shutdown N1 and N2 -> Impact (unable to write to the fuse mounted share)
- Shutdown N3 and N4 -> Impact (unable to write to the fuse mounted share)
-
Environment
- Red Hat Gluster Storage 3.2 and later
Subscriber exclusive content