Consistently seeing storage on HBAs in two servers go online/offline every few minutes while using RAIDarray.mpp software
Issue
- observed storage attached to HBAs on two servers bouncing between online and offline
- message symptoms include failing over the devices between nodes
Dec 10 11:20:04 NODE1 kernel: 10 [RAIDarray.mpp]PHSFT06:1 Failover command issued
Dec 10 11:20:19 NODE2 kernel: 10 [RAIDarray.mpp]PHSFT06:0 Failover command issued
Dec 10 11:20:30 NODE1 kernel: 10 [RAIDarray.mpp]PHSFT06:1 Failover command issued
Dec 10 11:20:41 NODE2 kernel: 10 [RAIDarray.mpp]PHSFT06:0 Failover command issued
Dec 10 11:20:56 NODE1 kernel: 10 [RAIDarray.mpp]PHSFT06:1 Failover command issued
Dec 10 11:21:10 NODE2 kernel: 10 [RAIDarray.mpp]PHSFT06:0 Failover command issued
:
- Same storage and luns shared between two servers
Environment
- Red Hat Enterprise Linux 5.3