stopping cman at the same time on two nodes fails to stop qdiskd on one of them when using master_wins mode in a RHEL 6 High Availability cluster
Issue
- Sometimes we have the problem during stopping cman on one cluster node
- When stopping
cmanon both nodes at once, one of them fails to stopqdiskd, and then I can't get it to stop in subsequent attempts either unless I force kill the daemon
# service cman stop
Stopping cluster:
Leaving fence domain... [ OK ]
Stopping gfs_controld... [ OK ]
Stopping dlm_controld... [ OK ]
Stopping fenced... [ OK ]
Stopping qdiskd...
[FAILED]
Environment
- Red Hat Enterprise Linux (RHEL) 6 with the High Availability Add On
cman-3.0.12.1-49.el6or later- Cluster configured to use a quorum device (
<quorumd/>exists in/etc/cluster/cluster.conf)- The quorum-device daemon is configured to use
master_winsmode through either:<quorumd master_wins="1"/>in/etc/cluster/cluster.conf, or- There are no
<heuristic/>s configured under<quorumd/>in/etc/cluster/cluster.confand it is a two-node cluster
- The quorum-device daemon is configured to use
- Stopping
cmanon both nodes right about the same time