After a mirror leg fails, the mirror LV is not converted to linear LV in RHEL 6
Issue
- After a storage failure, a complete site went down. This affected one mirror leg in a number of mirrored devices. Even after there were no remaining paths in the multipath device of the mirror leg, there was no change to linear.
- My cluster experienced a site failure with one storage array going down, but
rgmanagerresources became blocked or failed to stop
Environment
- Red Hat Enterprise Linux (RHEL) 6
lvm2- Using releases prior to
lvm2-2.02.104, OR In/etc/lvm/lvm.confdevices { ignore_lvm_mirrors = 0 }` or is unspecified
- Using releases prior to
Subscriber exclusive content