Oracle RAC node evicted or rebooted due to guest-level DM-Multipath queueing I/O on VMware Virtual Disks.

Solution Unverified - Updated -

Issue

  • Virtual machines hosting an Oracle RAC database cluster crash and reboot within a very tight window (coinciding within seconds of each other) during transient storage-level latency or path failover on the ESXi hypervisor.
  • In /var/log/messages, the Oracle watchdog (such as cssdmonitor or cssdagent) detects that the heartbeat daemon is unresponsive and triggers a hard reboot or kernel panic (fencing/eviction) to protect database integrity:
    [cssdagent(4612)]crsd has been unresponsive for 30 seconds. Fencing node.
    kernel: SysRq : Trigger a crash dump
  • Active DM-Multipath configurations map single-path virtual disks (e.g., VMware VMDKs or virtual RDMs presented as SCSI devices like /dev/sda, /dev/sdb, or /dev/sdf) inside the guest operating system.

Environment

  • Red Hat Enterprise Linux 8
  • Red Hat Enterprise Linux 9
  • VMware ESXi hypervisor
  • Oracle Real Application Clusters (RAC)
  • device-mapper-multipath (DM-Multipath) active in the guest OS