Getting AMQ222002 error code on Red Hat AMQ

Solution Verified - Updated -

Environment

  • Red Hat AMQ
    • 7.x

Issue

  • AMQ222002 error code is appearing in the artemis.log
  • AMQ Broker was forced to shutdown

Resolution

The specific message AMQ222002 simply means that the server executor service did not shutdown within 10 seconds so it was forced to shutdown.

Increase the logging level to point at any possible reason why the broker shutdown, see: Red Hat AMQ Product Documentation, Chapter 23. Logging for details.

Diagnostic Steps

Search for AMQ222002 error on the artemis.log located at {BROKER_INSTANCE_DIR}/log/artemis.log

This solution is part of Red Hat’s fast-track publication program, providing a huge library of solutions that Red Hat engineers have created while supporting our customers. To give you the knowledge you need the instant it becomes available, these articles may be presented in a raw and unedited form.