"Attached Changer" of tapeinfo command doesn't indicate correct information.

Solution Verified - Updated -

Issue

  • An application vendor is configuring Backup Software named Zmanda but they fails to configure backup job.
  • The application vendor insists this failure is caused by that OS (RHEL4) cannot recognize tape changer (DELL PowerVault TL2000) properly showing the result of "tapeinfo" command.
  • But we can operate tape changer via web interface of TL2000 properly.
  • Do you know any command to prove tape changer is properly configured by OS?

    # tapeinfo -f /dev/sg3
    Product Type: Tape Drive
    Vendor ID: 'IBM '
    Product ID: 'ULT3580-TD3 '
    Revision: '93G6'
    Attached Changer: No
    SerialNumber: '1210422339'
    MinBlock:1
    MaxBlock:16777215
    SCSI ID: 4
    SCSI LUN: 0
    Ready: yes
    BufferedMode: yes
    Medium Type: 0x38
    Density Code: 0x44
    BlockSize: 0
    DataCompEnabled: yes
    DataCompCapable: yes
    DataDeCompEnabled: yes
    CompType: 0x1
    DeCompType: 0x1
    BOP: yes
    Block Position: 0
    

Environment

  • Red Hat Enterprise Linux 4