Why multipath cannot recognize any of the EMC SAN Luns?
Issue
- In order to tune 'rr_min_io' value for EMC SYMMETRIX array on the RHEL 5.6 host, following entries were made in /etc/multipath.conf file:
devices {
device {
vendor EMC
product SYMMETRIX
path_grouping_policy multibus
getuid_callout /sbin/scsi_id -g -u -ppre-spc3-83 -s /block/%n
rr_min_io 100
}
}
The changes for rr_min_io parameter were immediately reflected and were verified using 'multipathd -k' interactive console.
# multipathd -k
> > show config
> > CTRL-D
However when the system is rebooted, multipath cannot recognize any of the EMC SAN Luns. Removing the customized entry and restarting multipathd service brings back the EMC SAN Lun.
Environment
- Red Hat Enterprise Linux
- EMC Symmetrix
Subscriber exclusive content
A Red Hat subscription provides unlimited access to our knowledgebase of over 48,000 articles and solutions.
Welcome! Check out the Getting Started with Red Hat page for quick tours and guides for common tasks.
