fence_ipmilan fails or times out after updating fence-agents even though the timeout option is specified in the configuration in a RHEL 6 High Availability cluster
Issue
- I have a 2 node Red Hat High availability cluster. After upgrading to RHEL 6.7, the
timeout
option no longer is valid for the fencing agents defined in the stanzasfencedevices
section of/etc/cluster/cluster.conf
. - When `ccs_config_validate is ran it fails with the following output:
# ccs_config_validate -f /etc/cluster/cluster.conf
Relax-NG validity error : Extra element fencedevices in interleave
tempfile:8: element fencedevices: Relax-NG validity error : Element cluster failed to validate content
Configuration fails to validate
- After patching the operating system, the
cluster.conf
no longer validates. Manually copying the samecluster.conf
to another server with older RHEL6.6 release, it validates fine.
[root@node1 cluster ]# ccs_config_validate
Relax-NG validity error : Extra element fencedevices in interleave
tempfile:49: element fencedevices: Relax-NG validity error : Element cluster failed to validate content
tempfile:36: element device: validity error : IDREF attribute name references an unknown ID "IPMI-02"
tempfile:29: element device: validity error : IDREF attribute name references an unknown ID "IPMI-01"
Configuration fails to validate
Environment
- Red Hat Enterprise Linux (RHEL) 6 with the High Availability Add On
fence-agents-4.0.15-8.el6.x86_64
or later- One or more
fencedevice
s configured in/etc/cluster/cluster.conf
using one of the following agents:fence_ilo3
fence_ilo4
fence_imm
fence_idrac
fence_ipmilan
Subscriber exclusive content