B.2. Integrated Lights-Out (iLO)
iLO 是惠普提供的一个远程电源功能的接口,这些功能包括电源管理和服务器监控。
- pm_type
- 把这个选项设置为
pxe_ilo。 - pm_user, pm_password
- iLO 的用户名和密码。
- pm_addr
- iLO 接口的 IP 地址。
额外注记
- 编辑
/etc/ironic/ironic.conf文件,把pxe_ilo加入到enabled_drivers选项来启用这个驱动。 - director 需要为 iLo 安装一组额外的工具程序。安装
python-proliantutils软件包并重启openstack-ironic-conductor服务:$ sudo yum install python-proliantutils $ sudo systemctl restart openstack-ironic-conductor.service
- 为了成功进行內省,HP 节点必须是 2015 的固件版本。director 已经经过测试可以使用固件版本为 1.85(May 13 2015)的节点。

Where did the comment section go?
Red Hat's documentation publication system recently went through an upgrade to enable speedier, more mobile-friendly content. We decided to re-evaluate our commenting platform to ensure that it meets your expectations and serves as an optimal feedback mechanism. During this redesign, we invite your input on providing feedback on Red Hat documentation via the discussion platform.