Network Functions Virtualization Planning and Configuration Guide

Red Hat OpenStack Platform 16.0

Planning and Configuring the Network Functions Virtualization (NFV) OpenStack Deployment

OpenStack Documentation Team

Abstract

This guide contains important planning information and describes the configuration procedures for single root input/output virtualization (SR-IOV) and dataplane development kit (DPDK) for network functions virtualization infrastructure (NFVi) in your Red Hat OpenStack Platform deployment.

Preface

Red Hat OpenStack Platform provides the foundation to build a private or public cloud on top of Red Hat Enterprise Linux. It offers a massively scalable, fault-tolerant platform for the development of cloud-enabled workloads.

This guide describes the steps to plan and configure single root input/output virtualization(SR-IOV) and Open vSwitch with Data Plane Development Kit (OVS-DPDK) using the Red Hat OpenStack Platform director for NFV deployments.

Chapter 1. Overview of NFV

Network Functions Virtualization (NFV) is a software solution that virtualizes a network function, such as a network switch, on general purpose, cloud-based infrastructure. NFV allows the Communication Service Provider to move away from traditional or proprietary hardware.

For a high-level overview of NFV concepts, see the Network Functions Virtualization Product Guide.

Note

OVS-DPDK and SR-IOV configuration depends on your hardware and topology. This guide provides examples for CPU assignments, memory allocation, and NIC configurations that might vary from your topology and use case.

Use Red Hat OpenStack Platform director to isolate specific network types, for example, external, project, internal API, and so on. You can deploy a network on a single network interface, or distributed over a multiple-host network interface. With Open vSwitch you can create bonds by assigning multiple interfaces to a single bridge. Configure network isolation in a Red Hat OpenStack Platform installation with template files. If you do not provide template files, the service networks deploy on the provisioning network. There are two types of template configuration files:

  • network-environment.yaml - this file contains network details, such as subnets and IP address ranges, for the overcloud nodes. This file also contains the different settings that override the default parameter values for various scenarios.
  • Host network templates, for example, compute.yaml and controller.yaml - define the network interface configuration for the overcloud nodes. The values of the network details are provided by the network-environment.yaml file.

These heat template files are located at /usr/share/openstack-tripleo-heat-templates/ on the undercloud node.

The Hardware requirements and Software requirements sections provide more details on how to plan and configure the heat template files for NFV using the Red Hat OpenStack Platform director.

Note

You can edit YAML files to configure NFV. For an introduction to the YAML file format, see: YAML in a Nutshell.

Chapter 2. Hardware requirements

This section describes the hardware requirements for NFV.

You can use Red Hat Technologies Ecosystem to check for a list of certified hardware, software, cloud providers, and components. Choose the category and select the product version.

For a complete list of the certified hardware for Red Hat OpenStack Platform, see Red Hat OpenStack Platform certified hardware.

2.1. Tested NICs

For a list of tested NICs for NFV, see Network Adapter Support.

If you configure OVS-DPDK on Mellanox ConnectX-4 or ConnectX-5 network interfaces, you must set the corresponding kernel driver in the compute-ovs-dpdk.yaml file:

members
 - type: ovs_dpdk_port
    name: dpdk0
    driver: mlx5_core
    members:
    - type: interface
      name: enp3s0f0

2.2. Discovering your NUMA node topology

When you plan your deployment, you must understand the NUMA topology of your Compute node to partition the CPU and memory resources for optimum performance. To determine the NUMA information, perform one of the following tasks:

  • Enable hardware introspection to retrieve this information from bare-metal nodes.
  • Log on to each bare-metal node to manually collect the information.
Note

You must install and configure the undercloud before you can retrieve NUMA information through hardware introspection. For more information about undercloud configuration, see: Director Installation and Usage Guide.

Retrieving hardware introspection details

The Bare Metal service hardware-inspection-extras feature is enabled by default, and you can use it to retrieve hardware details for overcloud configuration. For more information about the inspection_extras parameter in the undercloud.conf file, see Configuring the Director.

For example, the numa_topology collector is part of the hardware-inspection extras and includes the following information for each NUMA node:

  • RAM (in kilobytes)
  • Physical CPU cores and their sibling threads
  • NICs associated with the NUMA node

To retrieve the information listed above, substitute <UUID> with the UUID of the bare-metal node to complete the following command:

# openstack baremetal introspection data save <UUID> | jq .numa_topology

The following example shows the retrieved NUMA information for a bare-metal node:

{
  "cpus": [
    {
      "cpu": 1,
      "thread_siblings": [
        1,
        17
      ],
      "numa_node": 0
    },
    {
      "cpu": 2,
      "thread_siblings": [
        10,
        26
      ],
      "numa_node": 1
    },
    {
      "cpu": 0,
      "thread_siblings": [
        0,
        16
      ],
      "numa_node": 0
    },
    {
      "cpu": 5,
      "thread_siblings": [
        13,
        29
      ],
      "numa_node": 1
    },
    {
      "cpu": 7,
      "thread_siblings": [
        15,
        31
      ],
      "numa_node": 1
    },
    {
      "cpu": 7,
      "thread_siblings": [
        7,
        23
      ],
      "numa_node": 0
    },
    {
      "cpu": 1,
      "thread_siblings": [
        9,
        25
      ],
      "numa_node": 1
    },
    {
      "cpu": 6,
      "thread_siblings": [
        6,
        22
      ],
      "numa_node": 0
    },
    {
      "cpu": 3,
      "thread_siblings": [
        11,
        27
      ],
      "numa_node": 1
    },
    {
      "cpu": 5,
      "thread_siblings": [
        5,
        21
      ],
      "numa_node": 0
    },
    {
      "cpu": 4,
      "thread_siblings": [
        12,
        28
      ],
      "numa_node": 1
    },
    {
      "cpu": 4,
      "thread_siblings": [
        4,
        20
      ],
      "numa_node": 0
    },
    {
      "cpu": 0,
      "thread_siblings": [
        8,
        24
      ],
      "numa_node": 1
    },
    {
      "cpu": 6,
      "thread_siblings": [
        14,
        30
      ],
      "numa_node": 1
    },
    {
      "cpu": 3,
      "thread_siblings": [
        3,
        19
      ],
      "numa_node": 0
    },
    {
      "cpu": 2,
      "thread_siblings": [
        2,
        18
      ],
      "numa_node": 0
    }
  ],
  "ram": [
    {
      "size_kb": 66980172,
      "numa_node": 0
    },
    {
      "size_kb": 67108864,
      "numa_node": 1
    }
  ],
  "nics": [
    {
      "name": "ens3f1",
      "numa_node": 1
    },
    {
      "name": "ens3f0",
      "numa_node": 1
    },
    {
      "name": "ens2f0",
      "numa_node": 0
    },
    {
      "name": "ens2f1",
      "numa_node": 0
    },
    {
      "name": "ens1f1",
      "numa_node": 0
    },
    {
      "name": "ens1f0",
      "numa_node": 0
    },
    {
      "name": "eno4",
      "numa_node": 0
    },
    {
      "name": "eno1",
      "numa_node": 0
    },
    {
      "name": "eno3",
      "numa_node": 0
    },
    {
      "name": "eno2",
      "numa_node": 0
    }
  ]
}

2.3. BIOS Settings

The following table describes the required BIOS settings for NFV:

Table 2.1. BIOS Settings

ParameterSetting

C3 Power State

Disabled.

C6 Power State

Disabled.

MLC Streamer

Enabled.

MLC Spacial Prefetcher

Enabled.

DCU Data Prefetcher

Enabled.

DCA

Enabled.

CPU Power and Performance

Performance.

Memory RAS and Performance Config → NUMA Optimized

Enabled.

Turbo Boost

Disabled.

VT-d

Enabled for Intel cards if VFIO functionality is needed.

Chapter 3. Software requirements

This section describes the supported configurations and drivers, and subscription details necessary for NFV.

3.1. Registering and enabling repositories

To install Red Hat OpenStack Platform, you must register Red Hat OpenStack Platform director using the Red Hat Subscription Manager, and subscribe to the required channels. See Registering your system for details.

Procedure

  1. Register your system with the Content Delivery Network, entering your Customer Portal user name and password when prompted.

    [stack@director ~]$ sudo subscription-manager register
  2. Determine the entitlement pool ID for Red Hat OpenStack Platform director, for example {Pool ID} from the following command and output:

    [stack@director ~]$ sudo subscription-manager list --available --all --matches="Red Hat OpenStack"
    Subscription Name:   Name of SKU
    Provides:            Red Hat Single Sign-On
                         Red Hat Enterprise Linux Workstation
                         Red Hat CloudForms
                         Red Hat OpenStack
                         Red Hat Software Collections (for RHEL Workstation)
                         Red Hat Virtualization
    SKU:                 SKU-Number
    Contract:            Contract-Number
    Pool ID:             {Pool-ID}-123456
    Provides Management: Yes
    Available:           1
    Suggested:           1
    Service Level:       Support-level
    Service Type:        Service-Type
    Subscription Type:   Sub-type
    Ends:                End-date
    System Type:         Physical
  3. Include the Pool ID value in the following command to attach the Red Hat OpenStack Platform 15 entitlement.

    [stack@director ~]$ sudo subscription-manager attach --pool={Pool-ID}-123456
  4. Disable the default repositories.

    subscription-manager repos --disable=*
  5. Enable the required repositories for Red Hat OpenStack Platform with NFV.

    $ sudo subscription-manager repos --enable=rhel-8-for-x86_64-baseos-eus-rpms \
    --enable=rhel-8-for-x86_64-appstream-eus-rpms \
    --enable=rhel-8-for-x86_64-highavailability-eus-rpms \
    --enable=ansible-2.8-for-rhel-8-x86_64-rpms \
    --enable=openstack-16-for-rhel-8-x86_64-rpms \
    --enable=rhel-8-for-x86_64-nfv-rpms \
    --enable=advanced-virt-for-rhel-8-x86_64-rpms \
    --enable=fast-datapath-for-rhel-8-x86_64-rpms
  6. Update your system so you have the latest base system packages.

    [stack@director ~]$ sudo dnf update -y
    [stack@director ~]$ sudo reboot
Note

You need a separate subscription to a Red Hat OpenStack Platform for Real Time SKU before you can access the rhel-8-server-nfv-rpms repository for Real Time KVM.

Note

To register your overcloud nodes, see Ansible Based Registration.

3.2. Supported configurations for NFV deployments

Red Hat OpenStack Platform (RHOSP) supports the following NFV deployments using director:

  • Single root I/O virtualization (SR-IOV)
  • Open vSwitch with Data Plane Development Kit (OVS-DPDK)

Additionally, you can deploy RHOSP with any of the following features:

Note

Red Hat’s embedded OpenDaylight SDN solution was deprecated in RHOSP 14. Red Hat support, including bug fixes, for OpenDaylight ends with the RHOSP 13 lifecycle, planned for June 27, 2021.

RHOSP NFV deployments with Open Virtual Network (OVN) as the default Software Defined Networking (SDN) solution are unsupported. Use the following steps to deploy RHOSP with the OVS mechanism driver:

Procedure

  1. Modify the containers-prepare-parameter.yaml file so that the neutron_driver parameter is set to null.

    parameter_defaults:
      ContainerImagePrepare:
      - push_destination: true
        set:
         neutron_driver: null
         ...
  2. Include the neutron-ovs.yaml environment file in the /usr/share/openstack-tripleo-heat-templates/environments/services directory with your deployment script.

    TEMPLATES=/usr/share/openstack-tripleo-heat-templates
    
    openstack overcloud deploy --templates \
    -e ${TEMPLATES}/environments/network-environment.yaml \
    -e ${TEMPLATES}/environments/network-isolation.yaml \
    -e ${TEMPLATES}/environments/services/neutron-ovs.yaml \
    -e ${TEMPLATES}/environments/services/neutron-ovs-dpdk.yaml \
    -e ${TEMPLATES}/environments/services/neutron-sriov.yaml \
    -e /home/stack/containers-prepare-parameter.yaml

3.3. Supported drivers

For a complete list of supported drivers, see Component, Plug-In, and Driver Support in Red Hat OpenStack Platform .

For a list of NICs tested for Red Hat OpenStack Platform deployments with NFV, see Tested NICs.

3.4. Compatibility with third-party software

For a complete list of products and services tested, supported, and certified to perform with Red Hat OpenStack Platform, see Third Party Software compatible with Red Hat OpenStack Platform. You can filter the list by product version and software category.

For a complete list of products and services tested, supported, and certified to perform with Red Hat Enterprise Linux, see Third Party Software compatible with Red Hat Enterprise Linux. You can filter the list by product version and software category.

Chapter 4. Network considerations

The undercloud host requires at least the following networks:

  • Provisioning network - Provides DHCP and PXE-boot functions to help discover bare-metal systems for use in the overcloud.
  • External network - A separate network for remote connectivity to all nodes. The interface connecting to this network requires a routable IP address, either defined statically, or generated dynamically from an external DHCP service.

The minimal overcloud network configuration includes the following NIC configurations:

  • Single NIC configuration - One NIC for the provisioning network on the native VLAN and tagged VLANs that use subnets for the different overcloud network types.
  • Dual NIC configuration - One NIC for the provisioning network and the other NIC for the external network.
  • Dual NIC configuration - One NIC for the provisioning network on the native VLAN, and the other NIC for tagged VLANs that use subnets for different overcloud network types.
  • Multiple NIC configuration - Each NIC uses a subnet for a different overcloud network type.

For more information on the networking requirements, see Networking requirements.

Chapter 5. Planning an SR-IOV deployment

Optimize single root I/O virtualization (SR-IOV) deployments for NFV by setting individual parameters based on your Compute node hardware.

See Discovering your NUMA node topology to evaluate your hardware impact on the SR-IOV parameters.

5.1. Hardware partitioning for an SR-IOV deployment

To achieve high performance with SR-IOV, partition the resources between the host and the guest.

OpenStack NFV Hardware Capacities 464931 0118 SR IOV

A typical topology includes 14 cores per NUMA node on dual socket Compute nodes. Both hyper-threading (HT) and non-HT cores are supported. Each core has two sibling threads. One core is dedicated to the host on each NUMA node. The virtual network function (VNF) handles the SR-IOV interface bonding. All the interrupt requests (IRQs) are routed on the host cores. The VNF cores are dedicated to the VNFs. They provide isolation from other VNFs and isolation from the host. Each VNF must use resources on a single NUMA node. The SR-IOV NICs used by the VNF must also be associated with that same NUMA node. This topology does not have a virtualization overhead. The host, OpenStack Networking (neutron), and Compute (nova) configuration parameters are exposed in a single file for ease, consistency, and to avoid incoherence that is fatal to proper isolation, causing preemption, and packet loss. The host and virtual machine isolation depend on a tuned profile, which defines the boot parameters and any Red Hat OpenStack Platform modifications based on the list of isolated CPUs.

5.2. Topology of an NFV SR-IOV deployment

The following image has two VNFs each with the management interface represented by mgt and the data plane interfaces. The management interface manages the ssh access, and so on. The data plane interfaces bond the VNFs to DPDK to ensure high availability, as VNFs bond the data plane interfaces using the DPDK library. The image also has two provider networks for redundancy. The Compute node has two regular NICs bonded together and shared between the VNF management and the Red Hat OpenStack Platform API management.

NFV SR-IOV deployment

The image shows a VNF that uses DPDK at an application level, and has access to SR-IOV virtual functions (VFs) and physical functions (PFs), for better availability or performance, depending on the fabric configuration. DPDK improves performance, while the VF/PF DPDK bonds provide support for failover, and high availability. The VNF vendor must ensure that the DPDK poll mode driver (PMD) supports the SR-IOV card that is being exposed as a VF/PF. The management network uses OVS, therefore the VNF sees a mgmt network device using the standard virtIO drivers. You can use that device to initially connect to the VNF, and ensure that the DPDK application bonds the two VF/PFs.

5.2.1. Topology for NFV SR-IOV without HCI

Observe the topology for SR-IOV without hyper-converged infrastructure (HCI) for NFV in the image below. It consists of compute and controller nodes with 1 Gbps NICs, and the director node.

NFV SR-IOV Topology without HCI

Chapter 6. Deploying SR-IOV technologies

In your Red Hat OpenStack Platform NFV deployment, you can achieve higher performance with single root I/O virtualization (SR-IOV), when you configure direct access from your instances to a shared PCIe resource through virtual resources.

6.1. Prerequisites

Note

Do not manually edit any values in /etc/tuned/cpu-partitioning-variables.conf that director heat templates modify.

6.2. Configuring SR-IOV

Note

The following CPU assignments, memory allocation, and NIC configurations are examples, and might be different from your use case.

  1. Generate the built-in ComputeSriov role to define nodes in the OpenStack cluster that run NeutronSriovAgent, NeutronSriovHostConfig, and default compute services.

    # openstack overcloud roles generate \
    -o /home/stack/templates/roles_data.yaml \
    Controller ComputeSriov
  2. To prepare the SR-IOV containers, include the neutron-sriov.yaml and roles_data.yaml files when you generate the overcloud_images.yaml file.

    sudo openstack tripleo container image prepare \
      --roles-file ~/templates/roles_data.yaml \
      -e /usr/share/openstack-tripleo-heat-templates/environments/services/neutron-sriov.yaml \
      -e ~/containers-prepare-parameter.yaml \
      --output-env-file=/home/stack/templates/overcloud_images.yaml

    For more information on container image preparation, see Director Installation and Usage.

  3. Configure the parameters for the SR-IOV nodes under parameter_defaults appropriately for your cluster, and your hardware configuration. Typically, you add these settings to the network-environment.yaml file.

      NeutronNetworkType: 'vlan'
      NeutronNetworkVLANRanges:
        - tenant:22:22
        - tenant:25:25
      NeutronTunnelTypes: ''
  4. In the same file, configure role specific parameters for SR-IOV compute nodes.

    Note

    The numvfs parameter replaces the NeutronSriovNumVFs parameter in the network configuration templates. Red Hat does not support modification of the NeutronSriovNumVFs parameter or the numvfs parameter after deployment. If you modify either parameter after deployment, it might cause a disruption for the running instances that have an SR-IOV port on that physical function (PF). In this case, you must hard reboot these instances to make the SR-IOV PCI device available again. The NovaVcpuPinSet parameter is now deprecated, and is replaced by NovaComputeCpuDedicatedSet for dedicated, pinned workflows.

      ComputeSriovParameters:
        IsolCpusList: "1-19,21-39"
        KernelArgs: "default_hugepagesz=1GB hugepagesz=1G hugepages=32 iommu=pt intel_iommu=on isolcpus=1-19,21-39"
        TunedProfileName: "cpu-partitioning"
        NeutronBridgeMappings:
          - tenant:br-link0
        NeutronPhysicalDevMappings:
          - tenant:p7p1
          - tenant:p7p2
        NovaPCIPassthrough:
          - devname: "p7p1"
            physical_network: "tenant"
          - devname: "p7p2"
            physical_network: "tenant"
        NovaComputeCpuDedicatedSet: '1-19,21-39'
        NovaReservedHostMemory: 4096
  5. Configure the SR-IOV enabled interfaces in the compute.yaml network configuration template. To create SR-IOV virtual functions (VFs), configure the interfaces as standalone NICs:

                 - type: sriov_pf
                    name: p7p3
                    mtu: 9000
                    numvfs: 10
                    use_dhcp: false
                    defroute: false
                    nm_controlled: true
                    hotplug: true
                    promisc: false
    
                  - type: sriov_pf
                    name: p7p4
                    mtu: 9000
                    numvfs: 10
                    use_dhcp: false
                    defroute: false
                    nm_controlled: true
                    hotplug: true
                    promisc: false
  6. Ensure that the list of default filters includes the value AggregateInstanceExtraSpecsFilter.

    NovaSchedulerDefaultFilters: ['AvailabilityZoneFilter','ComputeFilter','ComputeCapabilitiesFilter','ImagePropertiesFilter','ServerGroupAntiAffinityFilter','ServerGroupAffinityFilter','PciPassthroughFilter','AggregateInstanceExtraSpecsFilter']
  7. Run the overcloud_deploy.sh script.

6.3. NIC partitioning

This feature is available in this release as a Technology Preview, and therefore is not fully supported by Red Hat. It should only be used for testing, and should not be deployed in a production environment. For more information about Technology Preview features, see Scope of Coverage Details.

You can configure single root I/O virtualization (SR-IOV) so that an Red Hat OpenStack Platform host can use virtual functions (VFs).

When you partition a single, high-speed NIC into multiple VFs, you can use the NIC for both control and data plane traffic. You can then apply a QoS (Quality of Service) priority value to VF interfaces as desired.

Procedure

Ensure that you complete the following steps when creating the templates for an overcloud deployment:

  1. Use the interface type sriov_pf in an os-net-config role file to configure a physical function that the host can use.

            - type: sriov_pf
              name: <interface name>
              use_dhcp: false
              numvfs: <number of vfs>
              promisc: <true/false> #optional (Defaults to true)
    Note

    The numvfs parameter replaces the NeutronSriovNumVFs parameter in the network configuration templates. Red Hat does not support modification of the NeutronSriovNumVFs parameter or the numvfs parameter after deployment. If you modify either parameter after deployment, it might cause a disruption for the running instances that have an SR-IOV port on that physical function (PF). In this case, you must hard reboot these instances to make the SR-IOV PCI device available again.

  2. Use the interface type sriov_vf to configure virtual functions in a bond that the host can use.

                   - type: linux_bond
                     name: internal_bond
                     bonding_options: mode=active-backup
                     use_dhcp: false
                     members:
                     - type: sriov_vf
                       device: nic7
                       vfid: 1
                     - type: sriov_vf
                       device: nic8
                       vfid: 1
    
                   - type: vlan
                     vlan_id:
                       get_param: InternalApiNetworkVlanID
                     device: internal_bond
                     addresses:
                     - ip_netmask:
                         get_param: InternalApiIpSubnet
    • The VLAN tag must be unique across all VFs that belong to a common PF device. You must assign VLAN tags to an interface type:

      • linux_bond
      • ovs_bridge
      • ovs_dpdk_port
    • The applicable VF ID range starts at zero, and ends at the maximum number of VFs minus one.
  3. To reserve virtual functions for VMs, use the NovaPCIPassthrough parameter. You must assign a regex value to the address parameter to identify the VFs that you want to pass through to Nova, to be used by virtual instances, and not by the host.

    You can obtain these values from lspci, so, if necessary, boot a compute node into a Linux environment to obtain this information.

    The lspci command returns the address of each device in the format <bus>:<device>:<slot>. Enter these address values in the NovaPCIPassthrough parameter in the following format:

      NovaPCIPassthrough:
        - physical_network: "sriovnet2"
          address: {"domain": ".*", "bus": "06", "slot": "11", "function": "[5-7]"}
        - physical_network: "sriovnet2"
          address: {"domain": ".*", "bus": "06", "slot": "10", "function": "[5]"}
  4. Ensure that IOMMU is enabled on all nodes that require NIC partitioning. For example, if you want NIC Partitioning for compute nodes, enable IOMMU using the KernelArgs parameter for that role:

    parameter_defaults:
      ComputeParameters:
        KernelArgs: "intel_iommu=on iommu=pt"

Validation

  1. Check the number of VFs.

    [root@overcloud-compute-0 heat-admin]# cat /sys/class/net/p4p1/device/sriov_numvfs
    10
    [root@overcloud-compute-0 heat-admin]# cat /sys/class/net/p4p2/device/sriov_numvfs
    10
  2. Check Linux bonds.

    [root@overcloud-compute-0 heat-admin]# cat /proc/net/bonding/intapi_bond
    Ethernet Channel Bonding Driver: v3.7.1 (April 27, 2011)
    
    Bonding Mode: fault-tolerance (active-backup)
    Primary Slave: None
    Currently Active Slave: p4p1_1
    MII Status: up
    MII Polling Interval (ms): 0
    Up Delay (ms): 0
    Down Delay (ms): 0
    
    Slave Interface: p4p1_1
    MII Status: up
    Speed: 10000 Mbps
    Duplex: full
    Link Failure Count: 0
    Permanent HW addr: 16:b4:4c:aa:f0:a8
    Slave queue ID: 0
    
    Slave Interface: p4p2_1
    MII Status: up
    Speed: 10000 Mbps
    Duplex: full
    Link Failure Count: 0
    Permanent HW addr: b6:be:82:ac:51:98
    Slave queue ID: 0
    [root@overcloud-compute-0 heat-admin]# cat /proc/net/bonding/st_bond
    Ethernet Channel Bonding Driver: v3.7.1 (April 27, 2011)
    
    Bonding Mode: fault-tolerance (active-backup)
    Primary Slave: None
    Currently Active Slave: p4p1_3
    MII Status: up
    MII Polling Interval (ms): 0
    Up Delay (ms): 0
    Down Delay (ms): 0
    
    Slave Interface: p4p1_3
    MII Status: up
    Speed: 10000 Mbps
    Duplex: full
    Link Failure Count: 0
    Permanent HW addr: 9a:86:b7:cc:17:e4
    Slave queue ID: 0
    
    Slave Interface: p4p2_3
    MII Status: up
    Speed: 10000 Mbps
    Duplex: full
    Link Failure Count: 0
    Permanent HW addr: d6:07:f8:78:dd:5b
    Slave queue ID: 0
  3. List OVS bonds.

    [root@overcloud-compute-0 heat-admin]# ovs-appctl bond/show
    ---- bond_prov ----
    bond_mode: active-backup
    bond may use recirculation: no, Recirc-ID : -1
    bond-hash-basis: 0
    updelay: 0 ms
    downdelay: 0 ms
    lacp_status: off
    lacp_fallback_ab: false
    active slave mac: f2:ad:c7:00:f5:c7(dpdk2)
    
    slave dpdk2: enabled
      active slave
      may_enable: true
    
    slave dpdk3: enabled
      may_enable: true
    
    ---- bond_tnt ----
    bond_mode: active-backup
    bond may use recirculation: no, Recirc-ID : -1
    bond-hash-basis: 0
    updelay: 0 ms
    downdelay: 0 ms
    lacp_status: off
    lacp_fallback_ab: false
    active slave mac: b2:7e:b8:75:72:e8(dpdk0)
    
    slave dpdk0: enabled
      active slave
      may_enable: true
    
    slave dpdk1: enabled
      may_enable: true
  4. Show OVS connections.

    [root@overcloud-compute-0 heat-admin]# ovs-vsctl show
    cec12069-9d4c-4fa8-bfe4-decfdf258f49
        Manager "ptcp:6640:127.0.0.1"
            is_connected: true
        Bridge br-tenant
            fail_mode: standalone
            Port br-tenant
                Interface br-tenant
                    type: internal
            Port bond_tnt
                Interface "dpdk0"
                    type: dpdk
                    options: {dpdk-devargs="0000:82:02.2"}
                Interface "dpdk1"
                    type: dpdk
                    options: {dpdk-devargs="0000:82:04.2"}
        Bridge "sriov2"
            Controller "tcp:127.0.0.1:6633"
                is_connected: true
            fail_mode: secure
            Port "phy-sriov2"
                Interface "phy-sriov2"
                    type: patch
                    options: {peer="int-sriov2"}
            Port "sriov2"
                Interface "sriov2"
                    type: internal
        Bridge br-int
            Controller "tcp:127.0.0.1:6633"
                is_connected: true
            fail_mode: secure
            Port "int-sriov2"
                Interface "int-sriov2"
                    type: patch
                    options: {peer="phy-sriov2"}
            Port br-int
                Interface br-int
                    type: internal
            Port "vhu93164679-22"
                tag: 4
                Interface "vhu93164679-22"
                    type: dpdkvhostuserclient
                    options: {vhost-server-path="/var/lib/vhost_sockets/vhu93164679-22"}
            Port "vhu5d6b9f5a-0d"
                tag: 3
                Interface "vhu5d6b9f5a-0d"
                    type: dpdkvhostuserclient
                    options: {vhost-server-path="/var/lib/vhost_sockets/vhu5d6b9f5a-0d"}
            Port patch-tun
                Interface patch-tun
                    type: patch
                    options: {peer=patch-int}
            Port "int-sriov1"
                Interface "int-sriov1"
                    type: patch
                    options: {peer="phy-sriov1"}
            Port int-br-vfs
                Interface int-br-vfs
                    type: patch
                    options: {peer=phy-br-vfs}
        Bridge br-vfs
            Controller "tcp:127.0.0.1:6633"
                is_connected: true
            fail_mode: secure
            Port phy-br-vfs
                Interface phy-br-vfs
                    type: patch
                    options: {peer=int-br-vfs}
            Port bond_prov
                Interface "dpdk3"
                    type: dpdk
                    options: {dpdk-devargs="0000:82:04.5"}
                Interface "dpdk2"
                    type: dpdk
                    options: {dpdk-devargs="0000:82:02.5"}
            Port br-vfs
                Interface br-vfs
                    type: internal
        Bridge "sriov1"
            Controller "tcp:127.0.0.1:6633"
                is_connected: true
            fail_mode: secure
            Port "sriov1"
                Interface "sriov1"
                    type: internal
            Port "phy-sriov1"
                Interface "phy-sriov1"
                    type: patch
                    options: {peer="int-sriov1"}
        Bridge br-tun
            Controller "tcp:127.0.0.1:6633"
                is_connected: true
            fail_mode: secure
            Port br-tun
                Interface br-tun
                    type: internal
            Port patch-int
                Interface patch-int
                    type: patch
                    options: {peer=patch-tun}
            Port "vxlan-0a0a7315"
                Interface "vxlan-0a0a7315"
                    type: vxlan
                    options: {df_default="true", in_key=flow, local_ip="10.10.115.10", out_key=flow, remote_ip="10.10.115.21"}
        ovs_version: "2.10.0"

If you used NovaPCIPassthrough to pass VFs to instances, test by deploying an SR-IOV instance.

The following bond modes are supported:

  • balance-slb
  • active-backup

6.4. Configuring OVS hardware offload

This feature is available in this release as a Technology Preview, and therefore is not fully supported by Red Hat. It should only be used for testing, and should not be deployed in a production environment. For more information about Technology Preview features, see Scope of Coverage Details.

The procedure for OVS hardware offload configuration shares many of the same steps as configuring SR-IOV.

Procedure

  1. Generate the ComputeSriov role:

    openstack overcloud roles generate -o roles_data.yaml Controller ComputeSriov
  2. Configure the physical_network parameter to match your environment.

    • For VLAN, set the physical_network parameter to the name of the network you create in neutron after deployment. This value should also be in NeutronBridgeMappings.
    • For VXLAN, set the physical_network parameter to the string value null.
    • Ensure the OvsHwOffload parameter under role specific parameters has a value of true.

      Example:

      parameter_defaults:
        ComputeSriovParameters:
          IsolCpusList: 2-9,21-29,11-19,31-39
          KernelArgs: "default_hugepagesz=1GB hugepagesz=1G hugepages=128 intel_iommu=on iommu=pt"
          OvsHwOffload: true
          TunedProfileName: "cpu-partitioning"
          NeutronBridgeMappings:
            - tenant:br-tenant
          NeutronPhysicalDevMappings:
            - tenant:p7p1
            - tenant:p7p2
          NovaPCIPassthrough:
            - devname: "p7p1"
              physical_network: "null"
            - devname: "p7p2"
              physical_network: "null"
          NovaReservedHostMemory: 4096
          NovaComputeCpuDedicatedSet: 1-9,21-29,11-19,31-39
  3. Ensure that the list of default filters includes NUMATopologyFilter:

      NovaSchedulerDefaultFilters: [\'RetryFilter',\'AvailabilityZoneFilter',\'ComputeFilter',\'ComputeCapabilitiesFilter',\'ImagePropertiesFilter',\'ServerGroupAntiAffinityFilter',\'ServerGroupAffinityFilter',\'PciPassthroughFilter',\'NUMATopologyFilter']
  4. Configure one or more network interfaces intended for hardware offload in the compute-sriov.yaml configuration file:

    Note

    Do not use the NeutronSriovNumVFs parameter when configuring Open vSwitch hardware offload. The numvfs parameter specifies the number of VFs in a network configuration file used by os-net-config.

      - type: ovs_bridge
        name: br-tenant
        mtu: 9000
        members:
        - type: sriov_pf
          name: p7p1
          numvfs: 5
          mtu: 9000
          primary: true
          promisc: true
          use_dhcp: false
          link_mode: switchdev
    Note

    Do not configure Mellanox network interfaces as a nic-config interface type ovs-vlan because this prevents tunnel endpoints such as VXLAN from passing traffic due to driver limitations.

  5. Include the ovs-hw-offload.yaml file in the overcloud deploy command:

    TEMPLATES_HOME=”/usr/share/openstack-tripleo-heat-templates”
    CUSTOM_TEMPLATES=”/home/stack/templates”
    
    openstack overcloud deploy --templates \
      -r ${CUSTOM_TEMPLATES}/roles_data.yaml \
      -e ${TEMPLATES_HOME}/environments/ovs-hw-offload.yaml \
      -e ${CUSTOM_TEMPLATES}/network-environment.yaml \
      -e ${CUSTOM_TEMPLATES}/neutron-ovs.yaml

6.4.1. Verifying OVS hardware offload

  1. Confirm that a PCI device is in switchdev mode:

    # devlink dev eswitch show pci/0000:03:00.0
    pci/0000:03:00.0: mode switchdev inline-mode none encap enable
  2. Verify if offload is enabled in OVS:

    # ovs-vsctl get Open_vSwitch . other_config:hw-offload
    “true”

6.5. Deploying an instance for SR-IOV

Use host aggregates to separate high performance compute hosts. For information on creating host aggregates and associated flavors for scheduling see Creating host aggregates.

Note

Pinned CPU instances can be located on the same Compute node as unpinned instances. For more information, see Configuring CPU pinning on the Compute node in the Instances and Images Guide.

Deploy an instance for single root I/O virtualization (SR-IOV) by performing the following steps:

  1. Create a flavor.

    # openstack flavor create <flavor> --ram <MB> --disk <GB> --vcpus <#>
    Tip

    You can specify the NUMA affinity policy for PCI passthrough devices and SR-IOV interfaces by adding the extra spec hw:pci_numa_affinity_policy to your flavor. For more information, see Update flavor metadata in the Instance and Images Guide.

  2. Create the network.

    # openstack network create net1 --provider-physical-network tenant --provider-network-type vlan --provider-segment <VLAN-ID>
    # openstack subnet create subnet1 --network net1 --subnet-range 192.0.2.0/24 --dhcp
  3. Create the port.

    • Use vnic-type direct to create an SR-IOV virtual function (VF) port.

      # openstack port create --network net1 --vnic-type direct sriov_port
    • Use the following command to create a virtual function with hardware offload.

      # openstack port create --network net1 --vnic-type direct --binding-profile '{"capabilities": ["switchdev"]} sriov_hwoffload_port
    • Use vnic-type direct-physical to create an SR-IOV PF port.

      # openstack port create --network net1 --vnic-type direct-physical sriov_port
  4. Deploy an instance.

    # openstack server create --flavor <flavor> --image <image> --nic port-id=<id> <instance name>

6.6. Creating host aggregates

For better performance, deploy guests that have cpu pinning and hugepages. You can schedule high performance instances on a subset of hosts by matching aggregate metadata with flavor metadata.

Procedure

  1. Ensure that the AggregateInstanceExtraSpecsFilter value is included in the scheduler_default_filters parameter in the nova.conf file. This configuration can be set through the heat parameter NovaSchedulerDefaultFilters under role-specific parameters before deployment.

      ComputeOvsDpdkSriovParameters:
        NovaSchedulerDefaultFilters: ['AggregateInstanceExtraSpecsFilter', 'RetryFilter','AvailabilityZoneFilter','ComputeFilter','ComputeCapabilitiesFilter','ImagePropertiesFilter','ServerGroupAntiAffinityFilter','ServerGroupAffinityFilter','PciPassthroughFilter','NUMATopologyFilter']
    Note

    To add this parameter to the configuration of an exiting cluster, you can add it to the heat templates, and run the original deployment script again.

  2. Create an aggregate group for SR-IOV, and add relevant hosts. Define metadata, for example, sriov=true, that matches defined flavor metadata.

    # openstack aggregate create sriov_group
    # openstack aggregate add host sriov_group compute-sriov-0.localdomain
    # openstack aggregate set --property sriov=true sriov_group
  3. Create a flavor.

    # openstack flavor create <flavor> --ram <MB> --disk <GB> --vcpus <#>
  4. Set additional flavor properties. Note that the defined metadata, sriov=true, matches the defined metadata on the SR-IOV aggregate.

    openstack flavor set --property aggregate_instance_extra_specs:sriov=true --property hw:cpu_policy=dedicated --property hw:mem_page_size=1GB <flavor>

Chapter 7. Planning your OVS-DPDK deployment

To optimize your OVS-DPDK deployment, you should understand how to configure the OVS-DPDK parameters relative to your Compute node hardware. For more information about CPUs and NUMA topology, see: NFV performance considerations.

7.1. OVS-DPDK with CPU partitioning and NUMA topology

OVS-DPDK partitions the hardware resources for host, guests, and itself. The OVS-DPDK Poll Mode Drivers (PMDs) run DPDK active loops, which require dedicated CPU cores. Therefore you must allocate some CPUs, and huge pages, to OVS-DPDK.

A sample partitioning includes 16 cores per NUMA node on dual-socket Compute nodes. The traffic requires additional NICs because you cannot share NICs between the host and OVS-DPDK.

OpenStack NFV Hardware Capacities 464931 0118 OVS DPDK
Note

You must reserve DPDK PMD threads on both NUMA nodes, even if a NUMA node does not have an associated DPDK NIC.

For optimum OVS-DPDK performance, reserve a block of memory local to the NUMA node. Choose NICs associated with the same NUMA node that you use for memory and CPU pinning. Ensure that both bonded interfaces are from NICs on the same NUMA node.

7.2. Workflows and derived parameters

This feature is available in this release as a Technology Preview, and therefore is not fully supported by Red Hat. It should only be used for testing, and should not be deployed in a production environment. For more information about Technology Preview features, see Scope of Coverage Details.

You can use the OpenStack Workflow (mistral) service to derive parameters based on the capabilities of your available bare-metal nodes. Workflows use a YAML file to define a set of tasks and actions to perform. You can use a pre-defined workbook, derive_params.yaml, in the directory tripleo-common/workbooks/. This workbook provides workflows to derive each supported parameter from the results of Bare Metal introspection. The derive_params.yaml workflows use the formulas from tripleo-common/workbooks/derive_params_formulas.yaml to calculate the derived parameters.

Note

You can modify derive_params_formulas.yaml to suit your environment.

The derive_params.yaml workbook assumes all nodes for a particular composable role have the same hardware specifications. The workflow considers the flavor-profile association and nova placement scheduler to match nodes associated with a role, then uses the introspection data from the first node that matches the role.

For more information about Red Hat OpenStack Platform workflows, see Troubleshooting workflows and executions.

You can use the -p or --plan-environment-file option to add a custom plan_environment.yaml file, containing a list of workbooks and any input values, to the openstack overcloud deploy command. The resultant workflows merge the derived parameters back into the custom plan_environment.yaml, where they are available for the overcloud deployment.

For details on how to use the --plan-environment-file option in your deployment, see Plan Environment Metadata.

7.3. Derived OVS-DPDK parameters

The workflows in derive_params.yaml derive the DPDK parameters associated with the role that uses the ComputeNeutronOvsDpdk service.

The workflows can automatically derive the following parameters for OVS-DPDK. The NovaVcpuPinSet parameter is now deprecated, and is replaced by NovaComputeCpuDedicatedSet for dedicated, pinned workflows:

  • IsolCpusList
  • KernelArgs
  • NovaReservedHostMemory
  • NovaComputeCpuDedicatedSet
  • OvsDpdkCoreList
  • OvsDpdkSocketMemory
  • OvsPmdCoreList

The OvsDpdkMemoryChannels parameter cannot be derived from the introspection memory bank data because the format of memory slot names are inconsistent across different hardware environments.

In most cases, the default number of OvsDpdkMemoryChannels is four. Consult your hardware manual to determine the number of memory channels per socket, and update the default number with this value.

For more information about workflow parameters, see Section 8.1, “Deriving DPDK parameters with workflows”.

7.4. Calculating OVS-DPDK parameters manually

This section describes how OVS-DPDK uses parameters within the director network_environment.yaml heat templates to configure the CPU and memory for optimum performance. Use this information to evaluate the hardware support on your Compute nodes and how to partition the hardware to optimize your OVS-DPDK deployment.

Note

For more information on an how to generate these values with the derived_parameters.yaml workflow instead, see Overview of workflows and derived parameters.

Note

Always pair CPU sibling threads, or logical CPUs, together in the physical core when allocating CPU cores.

For details on how to determine the CPU and NUMA nodes on your Compute nodes, see Discovering your NUMA node topology. Use this information to map CPU and other parameters to support the host, guest instance, and OVS-DPDK process needs.

7.4.1. CPU parameters

OVS-DPDK uses the following parameters for CPU partitioning:

OvsPmdCoreList

Provides the CPU cores that are used for the DPDK poll mode drivers (PMD). Choose CPU cores that are associated with the local NUMA nodes of the DPDK interfaces. Use OvsPmdCoreList for the pmd-cpu-mask value in OVS. Observe the following recommendations for OvsPmdCoreList:

  • Pair the sibling threads together.
  • Exclude all cores from the OvsDpdkCoreList
  • Avoid allocating the logical CPUs of both thread siblings on the first physical core to both NUMA nodes as these should be used for the OvsDpdkCoreList parameter.
  • Performance depends on the number of physical cores allocated for this PMD Core list. On the NUMA node which is associated with DPDK NIC, allocate the required cores.
  • For NUMA nodes with a DPDK NIC, determine the number of physical cores required based on the performance requirement, and include all the sibling threads or logical CPUs for each physical core.
  • For NUMA nodes without DPDK NICs, allocate the sibling threads or logical CPUs of any physical core except the first physical core of the NUMA node. You need a minimal DPDK poll mode driver on the NUMA node without DPDK NICs present to properly create guest instances.
Note

You must reserve DPDK PMD threads on both NUMA nodes, even if a NUMA node does not have an associated DPDK NIC.

NovaComputeCpuDedicatedSet

A comma-separated list or range of physical host CPU numbers to which processes for pinned instance CPUs can be scheduled. For example, NovaComputeCpuDedicatedSet: [4-12,^8,15] reserves cores from 4-12 and 15, excluding 8.

  • Exclude all cores from the OvsPmdCoreList and the OvsDpdkCoreList.
  • Include all remaining cores.
  • Pair the sibling threads together.
NovaComputeCpuSharedSet
A comma-separated list or range of physical host CPU numbers used to determine the host CPUs for instance emulator threads. The recommended value for this parameter matches the value set for OvsDpdkCoreList.
IsolCpusList

A set of CPU cores isolated from the host processes. IsolCpusList is the isolated_cores value in the cpu-partitioning-variable.conf file for the tuned-profiles-cpu-partitioning component. Observe the following recommendations for IsolCpusList:

  • Match the list of cores in OvsPmdCoreList and NovaComputeCpuDedicatedSet.
  • Pair the sibling threads together.
OvsDpdkCoreList

Provides CPU cores for non data path OVS-DPDK processes, such as handler and revalidator threads. This parameter has no impact on overall data path performance on multi-NUMA node hardware. OvsDpdkCoreList is the dpdk-lcore-mask value in OVS, and these cores are shared with the host. Observe the following recommendations for OvsDpdkCoreList:

  • Allocate the first physical core, and sibling thread, from each NUMA node, even if the NUMA node has no associated DPDK NIC.
  • These cores must be mutually exclusive from the list of cores in OvsPmdCoreList and NovaComputeCpuDedicatedSet.
DerivePciWhitelistEnabled

To reserve virtual functions (VF) for VMs, use the NovaPCIPassthrough parameter to create a list of VFs passed through to Nova. VFs excluded from the list remain available for the host.

Red Hat recommends that you change the DerivePciWhitelistEnabled value to false from the default of true, and then manually configure the list in the NovaPCIPassthrough parameter.

For each VF in the list, populate the address parameter with a regular expression that resolves to the address value.

The following is an example of the manual list creation process. If NIC partitioning is enabled in a device named eno2, list the PCI addresses of the VFs with the following command:

[heat-admin@compute-0 ~]$ ls -lh /sys/class/net/eno2/device/ | grep virtfn
lrwxrwxrwx. 1 root root    0 Apr 16 09:58 virtfn0 -> ../0000:18:06.0
lrwxrwxrwx. 1 root root    0 Apr 16 09:58 virtfn1 -> ../0000:18:06.1
lrwxrwxrwx. 1 root root    0 Apr 16 09:58 virtfn2 -> ../0000:18:06.2
lrwxrwxrwx. 1 root root    0 Apr 16 09:58 virtfn3 -> ../0000:18:06.3
lrwxrwxrwx. 1 root root    0 Apr 16 09:58 virtfn4 -> ../0000:18:06.4
lrwxrwxrwx. 1 root root    0 Apr 16 09:58 virtfn5 -> ../0000:18:06.5
lrwxrwxrwx. 1 root root    0 Apr 16 09:58 virtfn6 -> ../0000:18:06.6
lrwxrwxrwx. 1 root root    0 Apr 16 09:58 virtfn7 -> ../0000:18:06.7

In this case, the VFs 0, 4, and 6 are used by eno2 for NIC Partitioning. Manually configure NovaPCIPassthrough to include VFs 1-3, 5, and 7, and consequently exclude VFs 0,4, and 6, as in the following example:

NovaPCIPassthrough:
    - physical_network: "sriovnet2"
      address: {"domain": ".*", "bus": "18", "slot": "06", "function": "[1-3]"}
    - physical_network: "sriovnet2"
      address: {"domain": ".*", "bus": "18", "slot": "06", "function": "[5]"}
    - physical_network: "sriovnet2"
      address: {"domain": ".*", "bus": "18", "slot": "06", "function": "[7]"}

7.4.2. Memory parameters

OVS-DPDK uses the following memory parameters:

OvsDpdkMemoryChannels

Maps memory channels in the CPU per NUMA node. OvsDpdkMemoryChannels is the other_config:dpdk-extra=”-n <value>” value in OVS. Observe the following recommendations for OvsDpdkMemoryChannels:

  • Use dmidecode -t memory or your hardware manual to determine the number of memory channels available.
  • Use ls /sys/devices/system/node/node* -d to determine the number of NUMA nodes.
  • Divide the number of memory channels available by the number of NUMA nodes.
NovaReservedHostMemory

Reserves memory in MB for tasks on the host. NovaReservedHostMemory is the reserved_host_memory_mb value for the Compute node in nova.conf. Observe the following recommendation for NovaReservedHostMemory:

  • Use the static recommended value of 4096 MB.
OvsDpdkSocketMemory

Specifies the amount of memory in MB to pre-allocate from the hugepage pool, per NUMA node. OvsDpdkSocketMemory is the other_config:dpdk-socket-mem value in OVS. Observe the following recommendations for OvsDpdkSocketMemory:

  • Provide as a comma-separated list.
  • For a NUMA node without a DPDK NIC, use the static recommendation of 1024 MB (1GB)
  • Calculate the OvsDpdkSocketMemory value from the MTU value of each NIC on the NUMA node.
  • The following equation approximates the value for OvsDpdkSocketMemory:

    • MEMORY_REQD_PER_MTU = (ROUNDUP_PER_MTU + 800) * (4096 * 64) Bytes

      • 800 is the overhead value.
      • 4096 * 64 is the number of packets in the mempool.
  • Add the MEMORY_REQD_PER_MTU for each of the MTU values set on the NUMA node and add another 512 MB as buffer. Round the value up to a multiple of 1024.

Sample Calculation - MTU 2000 and MTU 9000

DPDK NICs dpdk0 and dpdk1 are on the same NUMA node 0, and configured with MTUs 900, and 2000 respectively. The sample calculation to derive the memory required is as follows:

  1. Round off the MTU values to the nearest multiple of 1024 bytes.

    The MTU value of 9000 becomes 9216 bytes.
    The MTU value of 2000 becomes 2048 bytes.
  2. Calculate the required memory for each MTU value based on these rounded byte values.

    Memory required for 9000 MTU = (9216 + 800) * (4096*64) = 2625634304
    Memory required for 2000 MTU = (2048 + 800) * (4096*64) = 746586112
  3. Calculate the combined total memory required, in bytes.

    2625634304 + 746586112 + 536870912 = 3909091328 bytes.

    This calculation represents (Memory required for MTU of 9000) + (Memory required for MTU of 2000) + (512 MB buffer).

  4. Convert the total memory required into MB.

    3909091328 / (1024*1024) = 3728 MB.
  5. Round this value up to the nearest 1024.

    3724 MB rounds up to 4096 MB.
  6. Use this value to set OvsDpdkSocketMemory.

        OvsDpdkSocketMemory: “4096,1024”

Sample Calculation - MTU 2000

DPDK NICs dpdk0 and dpdk1 are on the same NUMA node 0, and each are configured with MTUs of 2000. The sample calculation to derive the memory required is as follows:

  1. Round off the MTU values to the nearest multiple of 1024 bytes.

    The MTU value of 2000 becomes 2048 bytes.
  2. Calculate the required memory for each MTU value based on these rounded byte values.

    Memory required for 2000 MTU = (2048 + 800) * (4096*64) = 746586112
  3. Calculate the combined total memory required, in bytes.

    746586112 + 536870912 = 1283457024 bytes.

    This calculation represents (Memory required for MTU of 2000) + (512 MB buffer).

  4. Convert the total memory required into MB.

    1283457024 / (1024*1024) = 1224 MB.
  5. Round this value up to the nearest multiple of 1024.

    1224 MB rounds up to 2048 MB.
  6. Use this value to set OvsDpdkSocketMemory.

        OvsDpdkSocketMemory: “2048,1024”

7.4.3. Networking parameters

NeutronDpdkDriverType
Sets the driver type used by DPDK. Use the default value of vfio-pci.
NeutronDatapathType
Datapath type for OVS bridges. DPDK uses the default value of netdev.
NeutronVhostuserSocketDir
Sets the vhost-user socket directory for OVS. Use /var/lib/vhost_sockets for vhost client mode.

7.4.4. Other parameters

NovaSchedulerDefaultFilters
Provides an ordered list of filters that the Compute node uses to find a matching Compute node for a requested guest instance.
VhostuserSocketGroup
Sets the vhost-user socket directory group. The default value is qemu. Set VhostuserSocketGroup to hugetlbfs so that the ovs-vswitchd and qemu processes can access the shared huge pages and unix socket that configures the virtio-net device. This value is role-specific and should be applied to any role leveraging OVS-DPDK.
KernelArgs

Provides multiple kernel arguments to /etc/default/grub for the Compute node at boot time. Add the following values based on your configuration:

  • hugepagesz: Sets the size of the huge pages on a CPU. This value can vary depending on the CPU hardware. Set to 1G for OVS-DPDK deployments (default_hugepagesz=1GB hugepagesz=1G). Use this command to check for the pdpe1gb CPU flag that confirms your CPU supports 1G.

    lshw -class processor | grep pdpe1gb
  • hugepages count: Sets the number of huge pages available based on available host memory. Use most of your available memory, except NovaReservedHostMemory. You must also configure the huge pages count value within the flavor of your Compute nodes.
  • iommu: For Intel CPUs, add “intel_iommu=on iommu=pt”`
  • isolcpus: Sets the CPU cores for tuning. This value matches IsolCpusList.

7.4.5. Instance extra specifications

Before deploying instances in an NFV environment, create a flavor that utilizes CPU pinning, huge pages, and emulator thread pinning.

hw:cpu_policy
When this parameter is set to dedicated, the guest uses pinned CPUs. Instances created from a flavor with this parameter set have an effective overcommit ratio of 1:1. The default value is shared.
hw:mem_page_size

Set this parameter to a valid string of a specific value with standard suffix (For example, 4KB, 8MB, or 1GB). Use 1GB to match the hugepagesz boot parameter. Calculate the number of huge pages available for the virtual machines by subtracting OvsDpdkSocketMemory from the boot parameter. The following values are also valid:

  • small (default) - The smallest page size is used
  • large - Only use large page sizes. (2MB or 1GB on x86 architectures)
  • any - The compute driver can attempt to use large pages, but defaults to small if none available.
hw:emulator_threads_policy
Set the value of this parameter to share so that emulator threads are locked to CPUs that you’ve identified in the heat parameter, NovaComputeCpuSharedSet. If an emulator thread is running on a vCPU with the poll mode driver (PMD) or real-time processing, you can experience negative effects, such as packet loss.

7.5. Two NUMA node example OVS-DPDK deployment

The Compute node in the following example includes two NUMA nodes:

  • NUMA 0 has cores 0-7. The sibling thread pairs are (0,1), (2,3), (4,5), and (6,7)
  • NUMA 1 has cores 8-15. The sibling thread pairs are (8,9), (10,11), (12,13), and (14,15).
  • Each NUMA node connects to a physical NIC, namely NIC1 on NUMA 0, and NIC2 on NUMA 1.
OpenStack NFV NUMA Nodes 453316 0717 ECE OVS DPDK Deployment
Note

Reserve the first physical cores or both thread pairs on each NUMA node (0,1 and 8,9) for non-datapath DPDK processes, such as OvsDpdkCoreList.

This example also assumes a 1500 MTU configuration, so the OvsDpdkSocketMemory is the same for all use cases:

OvsDpdkSocketMemory: “1024,1024”

NIC 1 for DPDK, with one physical core for PMD

In this use case, you allocate one physical core on NUMA 0 for PMD. You must also allocate one physical core on NUMA 1, even though DPDK is not enabled on the NIC for that NUMA node. The remaining cores, not reserved for OvsDpdkCoreList, are allocated for guest instances. The resulting parameter settings are:

OvsPmdCoreList: “2,3,10,11”
NovaComputeCpuDedicatedSet: “4,5,6,7,12,13,14,15”

NIC 1 for DPDK, with two physical cores for PMD

In this use case, you allocate two physical cores on NUMA 0 for PMD. You must also allocate one physical core on NUMA 1, even though DPDK is not enabled on the NIC for that NUMA node. The remaining cores, not reserved for OvsDpdkCoreList, are allocated for guest instances. The resulting parameter settings are:

OvsPmdCoreList: “2,3,4,5,10,11”
NovaComputeCpuDedicatedSet: “6,7,12,13,14,15”

NIC 2 for DPDK, with one physical core for PMD

In this use case, you allocate one physical core on NUMA 1 for PMD. You must also allocate one physical core on NUMA 0, even though DPDK is not enabled on the NIC for that NUMA node. The remaining cores, not reserved for OvsDpdkCoreList, are allocated for guest instances. The resulting parameter settings are:

OvsPmdCoreList: “2,3,10,11”
NovaComputeCpuDedicatedSet: “4,5,6,7,12,13,14,15”

NIC 2 for DPDK, with two physical cores for PMD

In this use case, you allocate two physical cores on NUMA 1 for PMD. You must also allocate one physical core on NUMA 0, even though DPDK is not enabled on the NIC for that NUMA node. The remaining cores, not reserved for OvsDpdkCoreList, are allocated for guest instances. The resulting parameter settings are:

OvsPmdCoreList: “2,3,10,11,12,13”
NovaComputeCpuDedicatedSet: “4,5,6,7,14,15”

NIC 1 and NIC2 for DPDK, with two physical cores for PMD

In this use case, you allocate two physical cores on each NUMA node for PMD. The remaining cores, not reserved for OvsDpdkCoreList, are allocated for guest instances. The resulting parameter settings are:

OvsPmdCoreList: “2,3,4,5,10,11,12,13”
NovaComputeCpuDedicatedSet: “6,7,14,15”

7.6. Topology of an NFV OVS-DPDK deployment

This example deployment shows an OVS-DPDK configuration and consists of two virtual network functions (VNFs) with two interfaces each:

  • The management interface, represented by mgt.
  • The data plane interface.

In the OVS-DPDK deployment, the VNFs operate with inbuilt DPDK that supports the physical interface. OVS-DPDK enables bonding at the vSwitch level. For improved performance in your OVS-DPDK deployment, it is recommended that you separate kernel and OVS-DPDK NICs. To separate the management (mgt) network, connected to the Base provider network for the virtual machine, ensure you have additional NICs. The Compute node consists of two regular NICs for the Red Hat OpenStack Platform API management that can be reused by the Ceph API but cannot be shared with any OpenStack project.

NFV OVS-DPDK deployment

NFV OVS-DPDK topology

The following image shows the topology for OVS-DPDK for NFV. It consists of Compute and Controller nodes with 1 or 10 Gbps NICs, and the director node.

NFV OVS-DPDK Topology

Chapter 8. Configuring an OVS-DPDK deployment

This section deploys OVS-DPDK within the Red Hat OpenStack Platform environment. The overcloud usually consists of nodes in predefined roles such as Controller nodes, Compute nodes, and different storage node types. Each of these default roles contains a set of services defined in the core heat templates on the director node.

You must install and configure the undercloud before you can deploy the overcloud. See the Director Installation and Usage Guide for details.

Important

You must determine the best values for the OVS-DPDK parameters found in the network-environment.yaml file to optimize your OpenStack network for OVS-DPDK.

Note

Do not manually edit or change isolated_cores or other values in etc/tuned/cpu-partitioning-variables.conf that the director heat templates modify.

8.1. Deriving DPDK parameters with workflows

Important

This feature is available in this release as a Technology Preview, and therefore is not fully supported by Red Hat. It should only be used for testing, and should not be deployed in a production environment. For more information about Technology Preview features, see Scope of Coverage Details.

See Section 7.2, “Workflows and derived parameters” for an overview of the Mistral workflow for DPDK.

Prerequisites

You must have bare metal introspection, including hardware inspection extras (inspection_extras) enabled to provide the data retrieved by this workflow. Hardware inspection extras are enabled by default. For more information about hardware of the nodes, see: Inspecting the hardware of nodes.

Define the Workflows and Input Parameters for DPDK

The following list outlines the input parameters you can provide to the OVS-DPDK workflows:

num_phy_cores_per_numa_node_for_pmd
This input parameter specifies the required minimum number of cores for the NUMA node associated with the DPDK NIC. One physical core is assigned for the other NUMA nodes not associated with DPDK NIC. Ensure that this parameter is set to 1.
huge_page_allocation_percentage
This input parameter specifies the required percentage of total memory, excluding NovaReservedHostMemory, that can be configured as huge pages. The KernelArgs parameter is derived using the calculated huge pages based on the huge_page_allocation_percentage specified. Ensure that this parameter is set to 50.

The workflows calculate appropriate DPDK parameter values from these input parameters and the bare-metal introspection details.

To define the workflows and input parameters for DPDK:

  1. Copy the usr/share/openstack-tripleo-heat-templates/plan-samples/plan-environment-derived-params.yaml file to a local directory and set the input parameters to suit your environment.

      workflow_parameters:
        tripleo.derive_params.v1.derive_parameters:
          # DPDK Parameters #
          # Specifies the minimum number of CPU physical cores to be allocated for DPDK
          # PMD threads. The actual allocation will be based on network config, if
          # the a DPDK port is associated with a numa node, then this configuration
          # will be used, else 1.
          num_phy_cores_per_numa_node_for_pmd: 1
          # Amount of memory to be configured as huge pages in percentage. Ouf the
          # total available memory (excluding the NovaReservedHostMemory), the
          # specified percentage of the remaining is configured as huge pages.
          huge_page_allocation_percentage: 50
  2. Run the openstack overcloud deploy command and include the following information:

    • The update-plan-only option
    • The role file and all environment files specific to your environment
    • The plan-environment-derived-parms.yaml file with the --plan-environment-file optional argument

      $ openstack overcloud deploy --templates --update-plan-only \
      -r /home/stack/roles_data.yaml \
      -e /home/stack/<environment-file> \
      ... _#repeat as necessary_ ...
      **-p /home/stack/plan-environment-derived-params.yaml**

The output of this command shows the derived results, which are also merged into the plan-environment.yaml file.

Started Mistral Workflow tripleo.validations.v1.check_pre_deployment_validations. Execution ID: 55ba73f2-2ef4-4da1-94e9-eae2fdc35535
Waiting for messages on queue '472a4180-e91b-4f9e-bd4c-1fbdfbcf414f' with no timeout.
Removing the current plan files
Uploading new plan files
Started Mistral Workflow tripleo.plan_management.v1.update_deployment_plan. Execution ID: 7fa995f3-7e0f-4c9e-9234-dd5292e8c722
Plan updated.
Processing templates in the directory /tmp/tripleoclient-SY6RcY/tripleo-heat-templates
Invoking workflow (tripleo.derive_params.v1.derive_parameters) specified in plan-environment file
Started Mistral Workflow tripleo.derive_params.v1.derive_parameters. Execution ID: 2d4572bf-4c5b-41f8-8981-c84a363dd95b
Workflow execution is completed. result:
ComputeOvsDpdkParameters:
 IsolCpusList: 1,2,3,4,5,6,7,9,10,17,18,19,20,21,22,23,11,12,13,14,15,25,26,27,28,29,30,31
 KernelArgs: default_hugepagesz=1GB hugepagesz=1G hugepages=32 iommu=pt intel_iommu=on
   isolcpus=1,2,3,4,5,6,7,9,10,17,18,19,20,21,22,23,11,12,13,14,15,25,26,27,28,29,30,31
 NovaReservedHostMemory: 4096
 NovaComputeCpuDedicatedSet: 2,3,4,5,6,7,18,19,20,21,22,23,10,11,12,13,14,15,26,27,28,29,30,31
 OvsDpdkCoreList: 0,16,8,24
 OvsDpdkMemoryChannels: 4
 OvsDpdkSocketMemory: 1024,1024
 OvsPmdCoreList: 1,17,9,25
Note

The OvsDpdkMemoryChannels parameter cannot be derived from introspection details. In most cases, this value should be 4.

Deploy the overcloud with the derived parameters

To deploy the overcloud with these derived parameters:

  1. Copy the derived parameters from the deploy command output to the network-environment.yaml file.

      # DPDK compute node.
      ComputeOvsDpdkParameters:
        KernelArgs: default_hugepagesz=1GB hugepagesz=1G hugepages=32 iommu=pt intel_iommu=on
        TunedProfileName: "cpu-partitioning"
        IsolCpusList: "1,2,3,4,5,6,7,9,10,17,18,19,20,21,22,23,11,12,13,14,15,25,26,27,28,29,30,31"
        NovaComputeCpuDedicatedSet: ['2,3,4,5,6,7,18,19,20,21,22,23,10,11,12,13,14,15,26,27,28,29,30,31']
        NovaReservedHostMemory: 4096
        OvsDpdkSocketMemory: "1024,1024"
        OvsDpdkMemoryChannels: "4"
        OvsDpdkCoreList: "0,16,8,24"
        OvsPmdCoreList: "1,17,9,25"
    Note

    You must assign at least one CPU with sibling thread on each NUMA node with or without DPDK NICs present for DPDK PMD to avoid failures in creating guest instances.

    Note

    These parameters apply to the specific role, ComputeOvsDpdk. You can apply these parameters globally, but role-specific parameters overwrite any global parameters.

  2. Deploy the overcloud using the role file and all environment files specific to your environment.
 openstack overcloud deploy --templates \
 -r /home/stack/roles_data.yaml \
 -e /home/stack/<environment-file> \
... #repeat as necessary ...
Note

In a cluster with Compute, ComputeOvsDpdk, and ComputeSriov, the workflow applies the formula only for the ComputeOvsDpdk role, not Compute or ComputeSriovs.

8.2. OVS-DPDK topology

With Red Hat OpenStack Platform, you can create custom deployment roles, using the composable roles feature to add or remove services from each role. For more information on Composable Roles, see Composable Services and Custom Roles in Advanced Overcloud Customization.

This image shows a example OVS-DPDK topology with two bonded ports for the control plane and data plane:

OpenStack NFV Config Guide Topology 450694 0617 ECE OVS DPDK

To configure OVS-DPDK, perform the following tasks:

  • If you use composable roles, copy and modify the roles_data.yaml file to add the custom role for OVS-DPDK.
  • Update the appropriate network-environment.yaml file to include parameters for kernel arguments, and DPDK arguments.
  • Update the compute.yaml file to include the bridge for DPDK interface parameters.
  • Update the controller.yaml file to include the same bridge details for DPDK interface parameters.
  • Run the overcloud_deploy.sh script to deploy the overcloud with the DPDK parameters.
Note

This guide provides examples for CPU assignments, memory allocation, and NIC configurations that can vary from your topology and use case. For more information on hardware and configuration options, see: Network Functions Virtualization Product Guide and Chapter 2, Hardware requirements .

Prerequisites

Note

The Red Hat OpenStack Platform operates in OVS client mode for OVS-DPDK deployments.

8.3. Setting the MTU value for OVS-DPDK interfaces

Red Hat OpenStack Platform supports jumbo frames for OVS-DPDK. To set the maximum transmission unit (MTU) value for jumbo frames you must:

  • Set the global MTU value for networking in the network-environment.yaml file.
  • Set the physical DPDK port MTU value in the compute.yaml file. This value is also used by the vhost user interface.
  • Set the MTU value within any guest instances on the Compute node to ensure that you have a comparable MTU value from end to end in your configuration.
Note

VXLAN packets include an extra 50 bytes in the header. Calculate your MTU requirements based on these additional header bytes. For example, an MTU value of 9000 means the VXLAN tunnel MTU value is 8950 to account for these extra bytes.

Note

You do not need any special configuration for the physical NIC because the NIC is controlled by the DPDK PMD, and has the same MTU value set by the compute.yaml file. You cannot set an MTU value larger than the maximum value supported by the physical NIC.

To set the MTU value for OVS-DPDK interfaces:

  1. Set the NeutronGlobalPhysnetMtu parameter in the network-environment.yaml file.

    parameter_defaults:
      # MTU global configuration
      NeutronGlobalPhysnetMtu: 9000
    Note

    Ensure that the NeutronDpdkSocketMemory value in the network-environment.yaml file is large enough to support jumbo frames. For details, see Section 7.4.2, “Memory parameters” .

  2. Set the MTU value on the bridge to the Compute node in the controller.yaml file.

      -
        type: ovs_bridge
        name: br-link0
        use_dhcp: false
        members:
          -
            type: interface
            name: nic3
            mtu: 9000
  3. Set the MTU values for an OVS-DPDK bond in the compute.yaml file:

    - type: ovs_user_bridge
      name: br-link0
      use_dhcp: false
      members:
        - type: ovs_dpdk_bond
          name: dpdkbond0
          mtu: 9000
          rx_queue: 2
          members:
            - type: ovs_dpdk_port
              name: dpdk0
              mtu: 9000
              members:
                - type: interface
                  name: nic4
            - type: ovs_dpdk_port
              name: dpdk1
              mtu: 9000
              members:
                - type: interface
                  name: nic5

8.4. Configuring a firewall for security groups

Dataplane interfaces require high performance in a stateful firewall. To protect these interfaces, consider deploying a telco-grade firewall as a virtual network function (VNF).

To configure control plane interfaces, set the NeutronOVSFirewallDriver parameter to openvswitch. To use the flow-based OVS firewall driver, modify the network-environment.yaml file under parameter_defaults.

Example:

parameter_defaults:
  NeutronOVSFirewallDriver: openvswitch

Use the openstack port set command to disable the OVS firewall driver for dataplane interfaces.

Example:

openstack port set --no-security-group  --disable-port-security ${PORT}

8.5. Setting multiqueue for OVS-DPDK interfaces

Note

Multiqueue is experimental and unsupported.

To set the same number of queues for interfaces in OVS-DPDK on the Compute node, modify the compute.yaml file:

- type: ovs_user_bridge
  name: br-link0
  use_dhcp: false
  members:
    - type: ovs_dpdk_bond
      name: dpdkbond0
      mtu: 9000
      rx_queue: 2
      members:
        - type: ovs_dpdk_port
          name: dpdk0
          mtu: 9000
          members:
            - type: interface
              name: nic4
        - type: ovs_dpdk_port
          name: dpdk1
          mtu: 9000
          members:
            - type: interface
              name: nic5

8.6. Known limitations

Observe the following limitations when configuring OVS-DPDK with Red Hat OpenStack Platform for NFV:

  • Use Linux bonds for control plane networks. Ensure that both the PCI devices used in the bond are on the same NUMA node for optimum performance. Neutron Linux bridge configuration is not supported by Red Hat.
  • You require huge pages for every instance running on the hosts with OVS-DPDK. If huge pages are not present in the guest, the interface appears but does not function.
  • With OVS-DPDK, there is a performance degradation of services that use tap devices, such as Distributed Virtual Routing (DVR). The resulting performance is not suitable for a production environment.
  • When using OVS-DPDK, all bridges on the same Compute node must be of type ovs_user_bridge. The director may accept the configuration, but Red Hat OpenStack Platform does not support mixing ovs_bridge and ovs_user_bridge on the same node.

8.7. Creating a flavor and deploying an instance for OVS-DPDK

After you configure OVS-DPDK for your Red Hat OpenStack Platform deployment with NFV, you can create a flavor, and deploy an instance using the following steps:

  1. Create an aggregate group, and add relevant hosts for OVS-DPDK. Define metadata, for example dpdk=true, that matches defined flavor metadata.

     # openstack aggregate create dpdk_group
     # openstack aggregate add host dpdk_group [compute-host]
     # openstack aggregate set --property dpdk=true dpdk_group
    Note

    Pinned CPU instances can be located on the same Compute node as unpinned instances. For more information, see Configuring CPU pinning on the Compute node in the Instances and Images Guide.

  2. Create a flavor.

    # openstack flavor create <flavor> --ram <MB> --disk <GB> --vcpus <#>
  3. Set flavor properties. Note that the defined metadata, dpdk=true, matches the defined metadata in the DPDK aggregate.

    # openstack flavor set <flavor> --property dpdk=true --property hw:cpu_policy=dedicated --property hw:mem_page_size=1GB --property hw:emulator_threads_policy=isolate

    For details on the emulator threads policy for performance improvements, see: Configure Emulator Threads to run on a Dedicated Physical CPU .

  4. Create the network.

    # openstack network create net1 --provider-physical-network tenant --provider-network-type vlan --provider-segment <VLAN-ID>
    # openstack subnet create subnet1 --network net1 --subnet-range 192.0.2.0/24 --dhcp
  5. Optional: If you use multiqueue with OVS-DPDK, set the hw_vif_multiqueue_enabled property on the image that you want to use to create a instance:

    # openstack image set --property hw_vif_multiqueue_enabled=true <image>
  6. Deploy an instance.

    # openstack server create --flavor <flavor> --image <glance image> --nic net-id=<network ID> <server_name>

8.8. Troubleshooting the configuration

This section describes the steps to troubleshoot the OVS-DPDK configuration.

  1. Review the bridge configuration, and confirm that the bridge has datapath_type=netdev.

    # ovs-vsctl list bridge br0
    _uuid               : bdce0825-e263-4d15-b256-f01222df96f3
    auto_attach         : []
    controller          : []
    datapath_id         : "00002608cebd154d"
    datapath_type       : netdev
    datapath_version    : "<built-in>"
    external_ids        : {}
    fail_mode           : []
    flood_vlans         : []
    flow_tables         : {}
    ipfix               : []
    mcast_snooping_enable: false
    mirrors             : []
    name                : "br0"
    netflow             : []
    other_config        : {}
    ports               : [52725b91-de7f-41e7-bb49-3b7e50354138]
    protocols           : []
    rstp_enable         : false
    rstp_status         : {}
    sflow               : []
    status              : {}
    stp_enable          : false
  2. Confirm that the docker container neutron_ovs_agent is configured to start automatically.

    # docker inspect neutron_ovs_agent | grep -A1 RestartPolicy
                "RestartPolicy": {
                    "Name": "always",
  3. Optionally, you can view logs for errors, such as if the container fails to start.

    # less /var/log/containers/neutron/openvswitch-agent.log
  4. Confirm that the Poll Mode Driver CPU mask of the ovs-dpdk is pinned to the CPUs. In case of hyper threading, use sibling CPUs.

    For example, to check the sibling of CPU4, run the following command:

    # cat /sys/devices/system/cpu/cpu4/topology/thread_siblings_list
    4,20

    The sibling of CPU4 is CPU20, therefore proceed with the following command:

    # ovs-vsctl set Open_vSwitch . other_config:pmd-cpu-mask=0x100010

    Display the status:

    # tuna -t ovs-vswitchd -CP
    thread  ctxt_switches pid SCHED_ rtpri affinity voluntary nonvoluntary       cmd
    3161	OTHER 	0    	6	765023      	614	ovs-vswitchd
    3219   OTHER 	0    	6     	1        	0   	handler24
    3220   OTHER 	0    	6     	1        	0   	handler21
    3221   OTHER 	0    	6     	1        	0   	handler22
    3222   OTHER 	0    	6     	1        	0   	handler23
    3223   OTHER 	0    	6     	1        	0   	handler25
    3224   OTHER 	0    	6     	1        	0   	handler26
    3225   OTHER 	0    	6     	1        	0   	handler27
    3226   OTHER 	0    	6     	1        	0   	handler28
    3227   OTHER 	0    	6     	2        	0   	handler31
    3228   OTHER 	0    	6     	2        	4   	handler30
    3229   OTHER 	0    	6     	2        	5   	handler32
    3230   OTHER 	0    	6	953538      	431   revalidator29
    3231   OTHER 	0    	6   1424258      	976   revalidator33
    3232   OTHER 	0    	6   1424693      	836   revalidator34
    3233   OTHER 	0    	6	951678      	503   revalidator36
    3234   OTHER 	0    	6   1425128      	498   revalidator35
    *3235   OTHER 	0    	4	151123       	51       	pmd37*
    *3236   OTHER 	0   	20	298967       	48       	pmd38*
    3164   OTHER 	0    	6 	47575        	0  dpdk_watchdog3
    3165   OTHER 	0    	6	237634        	0   vhost_thread1
    3166   OTHER 	0    	6  	3665        	0       	urcu2

Chapter 9. Tuning a Red Hat OpenStack Platform environment

9.1. Pinning emulator threads

Emulator threads handle interrupt requests and non-blocking processes for virtual machine hardware emulation. These threads float across the CPUs that the guest uses for processing. If threads used for the poll mode driver (PMD) or real-time processing run on these guest CPUs, you can experience packet loss or missed deadlines.

You can separate emulator threads from VM processing tasks by pinning the threads to their own guest CPUs, increasing performance as a result.

9.1.1. Configuring CPUs to host emulator threads

To improve performance, reserve a subset of host CPUs identified in the OvsDpdkCoreList parameter for hosting emulator threads.

Procedure
  1. Deploy an overcloud with NovaComputeCpuSharedSet defined for a given role. The value of NovaComputeCpuSharedSet applies to the cpu_shared_set parameter in the nova.conf file for hosts within that role.

    parameter_defaults:
        ComputeOvsDpdkParameters:
            OvsDpdkCoreList: “0-1,16-17”
            NovaComputeCpuSharedSet: “0-1,16-17”
            NovaComputeCpuDedicatedSet: “2-15,18-31”
  2. Create a flavor to build instances with emulator threads separated into a shared pool.

    openstack flavor create --ram <size_mb> --disk <size_gb> --vcpus <vcpus> <flavor>
  3. Add the hw:emulator_threads_policy extra specification, and set the value to share. Instances created with this flavor will use the instance CPUs defined in the cpu_share_set parameter in the nova.conf file.

    openstack flavor set <flavor> --property hw:emulator_threads_policy=share
Note

You must set the cpu_share_set parameter in the nova.conf file to enable the share policy for this extra specification. You should use heat for this preferably, as editing nova.conf manually might not persist across redeployments.

9.1.2. Verify the emulator thread pinning

Procedure
  1. Identify the host and name for a given instance.

    openstack server show <instance_id>
  2. Use SSH to log on to the identified host as heat-admin.

    ssh heat-admin@compute-1
    [compute-1]$ sudo virsh dumpxml instance-00001 | grep `'emulatorpin cpuset'`

9.2. Enabling RT-KVM for NFV Workloads

To facilitate installing and configuring Red Hat Enterprise Linux 8.0 Real Time KVM (RT-KVM), Red Hat OpenStack Platform provides the following features:

  • A real-time Compute node role that provisions Red Hat Enterprise Linux for real-time.
  • The additional RT-KVM kernel module.
  • Automatic configuration of the Compute node.

9.2.1. Planning for your RT-KVM Compute nodes

You must use Red Hat certified servers for your RT-KVM Compute nodes. For more information, see: Red Hat Enterprise Linux for Real Time 7 certified servers.

For details on how to enable the rhel-8-server-nfv-rpms repository for RT-KVM, and ensuring your system is up to date, see: Registering and updating your undercloud.

Note

You need a separate subscription to a Red Hat OpenStack Platform for Real Time SKU before you can access this repository.

Building the real-time image

  1. Install the libguestfs-tools package on the undercloud to get the virt-customize tool:

    (undercloud) [stack@undercloud-0 ~]$ sudo dnf install libguestfs-tools
    Important

    If you install the libguestfs-tools package on the undercloud, disable iscsid.socket to avoid port conflicts with the tripleo_iscsid service on the undercloud:

    $ sudo systemctl disable --now iscsid.socket
  2. Extract the images:

    (undercloud) [stack@undercloud-0 ~]$ tar -xf /usr/share/rhosp-director-images/overcloud-full.tar
    (undercloud) [stack@undercloud-0 ~]$ tar -xf /usr/share/rhosp-director-images/ironic-python-agent.tar
  3. Copy the default image:

    (undercloud) [stack@undercloud-0 ~]$ cp overcloud-full.qcow2 overcloud-realtime-compute.qcow2
  4. Register your image to enable Red Hat repositories relevant to your customizations. Replace [username] and [password] with valid credentials in the following example.

    virt-customize -a overcloud-realtime-compute.qcow2 --run-command \
    'subscription-manager register --username=[username] --password=[password]' \
    subscription-manager release --set 8.1
    Note

    For security, you can remove credentials from the history file if they are used on the command prompt. You can delete individual lines in history using the history -d command followed by the line number.

  5. Find a list of pool IDs from your account’s subscriptions, and attach the appropriate pool ID to your image.

    sudo subscription-manager list --all --available | less
    ...
    virt-customize -a overcloud-realtime-compute.qcow2 --run-command \
    'subscription-manager attach --pool [pool-ID]'
  6. Add the repositories necessary for Red Hat OpenStack Platform with NFV.

    virt-customize -a overcloud-realtime-compute.qcow2 --run-command \
    'sudo subscription-manager repos --enable=rhel-8-for-x86_64-baseos-eus-rpms \
    --enable=rhel-8-for-x86_64-appstream-eus-rpms \
    --enable=rhel-8-for-x86_64-highavailability-eus-rpms \
    --enable=ansible-2.8-for-rhel-8-x86_64-rpms \
    --enable=openstack-16-for-rhel-8-x86_64-rpms \
    --enable=rhel-8-for-x86_64-nfv-rpms \
    --enable=advanced-virt-for-rhel-8-x86_64-rpms \
    --enable=fast-datapath-for-rhel-8-x86_64-rpms'
  7. Create a script to configure real-time capabilities on the image.

    (undercloud) [stack@undercloud-0 ~]$ cat <<'EOF' > rt.sh
      #!/bin/bash
    
      set -eux
    
      dnf -v -y --setopt=protected_packages= erase kernel.$(uname -m)
      dnf -v -y install kernel-rt kernel-rt-kvm tuned-profiles-nfv-host
      EOF
  8. Run the script to configure the real-time image:

    (undercloud) [stack@undercloud-0 ~]$ virt-customize -a overcloud-realtime-compute.qcow2 -v --run rt.sh 2>&1 | tee virt-customize.log
    Note

    If you see the following line in the rt.sh script output, "grubby fatal error: unable to find a suitable template", you can ignore this error.

  9. Examine the virt-customize.log file that resulted from the previous command, to check that the packages installed correctly using the rt.sh script .

    (undercloud) [stack@undercloud-0 ~]$ cat virt-customize.log | grep Verifying
    
      Verifying  : kernel-3.10.0-957.el7.x86_64                                 1/1
      Verifying  : 10:qemu-kvm-tools-rhev-2.12.0-18.el7_6.1.x86_64              1/8
      Verifying  : tuned-profiles-realtime-2.10.0-6.el7_6.3.noarch              2/8
      Verifying  : linux-firmware-20180911-69.git85c5d90.el7.noarch             3/8
      Verifying  : tuned-profiles-nfv-host-2.10.0-6.el7_6.3.noarch              4/8
      Verifying  : kernel-rt-kvm-3.10.0-957.10.1.rt56.921.el7.x86_64            5/8
      Verifying  : tuna-0.13-6.el7.noarch                                       6/8
      Verifying  : kernel-rt-3.10.0-957.10.1.rt56.921.el7.x86_64                7/8
      Verifying  : rt-setup-2.0-6.el7.x86_64                                    8/8
  10. Relabel SELinux:

    (undercloud) [stack@undercloud-0 ~]$ virt-customize -a overcloud-realtime-compute.qcow2 --selinux-relabel
  11. Extract vmlinuz and initrd:

    (undercloud) [stack@undercloud-0 ~]$ mkdir image
    (undercloud) [stack@undercloud-0 ~]$ guestmount -a overcloud-realtime-compute.qcow2 -i --ro image
    (undercloud) [stack@undercloud-0 ~]$ cp image/boot/vmlinuz-3.10.0-862.rt56.804.el7.x86_64 ./overcloud-realtime-compute.vmlinuz
    (undercloud) [stack@undercloud-0 ~]$ cp image/boot/initramfs-3.10.0-862.rt56.804.el7.x86_64.img ./overcloud-realtime-compute.initrd
    (undercloud) [stack@undercloud-0 ~]$ guestunmount image
    Note

    The software version in the vmlinuz and initramfs filenames vary with the kernel version.

  12. Upload the image:

    (undercloud) [stack@undercloud-0 ~]$ openstack overcloud image upload --update-existing --os-image-name overcloud-realtime-compute.qcow2

You now have a real-time image you can use with the ComputeOvsDpdkRT composable role on your selected Compute nodes.

Modifying BIOS settings on RT-KVM Compute nodes

To reduce latency on your RT-KVM Compute nodes, disable all options for the following parameters in your Compute node BIOS settings:

  • Power Management
  • Hyper-Threading
  • CPU sleep states
  • Logical processors

For descriptions of these settings and the impact of disabling them, see: Setting BIOS parameters. See your hardware manufacturer documentation for complete details on how to change BIOS settings.

9.2.2. Configuring OVS-DPDK with RT-KVM

Note

You must determine the best values for the OVS-DPDK parameters that you set in the network-environment.yaml file to optimize your OpenStack network for OVS-DPDK. For more details, see Section 8.1, “Deriving DPDK parameters with workflows”.

9.2.2.1. Generating the ComputeOvsDpdk composable role

Use the ComputeOvsDpdkRT role to specify Compute nodes for the real-time compute image.

Generate roles_data.yaml for the ComputeOvsDpdkRT role.

# (undercloud) [stack@undercloud-0 ~]$ openstack overcloud roles generate -o roles_data.yaml Controller ComputeOvsDpdkRT

9.2.2.2. Configuring the OVS-DPDK parameters

Important

Determine the best values for the OVS-DPDK parameters in the network-environment.yaml file to optimize your deployment. For more information, see Section 8.1, “Deriving DPDK parameters with workflows”.

  1. Add the NIC configuration for the OVS-DPDK role you use under resource_registry:

    resource_registry:
      # Specify the relative/absolute path to the config files you want to use for override the default.
      OS::TripleO::ComputeOvsDpdkRT::Net::SoftwareConfig: nic-configs/compute-ovs-dpdk.yaml
      OS::TripleO::Controller::Net::SoftwareConfig: nic-configs/controller.yaml
  2. Under parameter_defaults, set the OVS-DPDK, and RT-KVM parameters:

      # DPDK compute node.
      ComputeOvsDpdkRTParameters:
        KernelArgs: "default_hugepagesz=1GB hugepagesz=1G hugepages=32 iommu=pt intel_iommu=on isolcpus=1-7,17-23,9-15,25-31"
        TunedProfileName: "realtime-virtual-host"
        IsolCpusList: "1,2,3,4,5,6,7,9,10,17,18,19,20,21,22,23,11,12,13,14,15,25,26,27,28,29,30,31"
        NovaComputeCpuDedicatedSet: ['2,3,4,5,6,7,18,19,20,21,22,23,10,11,12,13,14,15,26,27,28,29,30,31']
        NovaReservedHostMemory: 4096
        OvsDpdkSocketMemory: "1024,1024"
        OvsDpdkMemoryChannels: "4"
        OvsDpdkCoreList: "0,16,8,24"
        OvsPmdCoreList: "1,17,9,25"
        VhostuserSocketGroup: "hugetlbfs"
      ComputeOvsDpdkRTImage: "overcloud-realtime-compute"

9.2.2.3. Deploying the overcloud

Deploy the overcloud for ML2-OVS:

(undercloud) [stack@undercloud-0 ~]$ openstack overcloud deploy \
--templates \
-r /home/stack/ospd-16-vlan-dpdk-ctlplane-bonding-rt/roles_data.yaml \
-e /usr/share/openstack-tripleo-heat-templates/environments/network-isolation.yaml \
-e /usr/share/openstack-tripleo-heat-templates/environments/services/neutron-ovs.yaml \
-e /usr/share/openstack-tripleo-heat-templates/environments/services/neutron-ovs-dpdk.yaml \
-e /home/stack/ospd-16-vxlan-dpdk-data-bonding-rt-hybrid/containers-prepare-parameter.yaml \
-e /home/stack/ospd-16-vxlan-dpdk-data-bonding-rt-hybrid/network-environment.yaml

9.2.3. Launching an RT-KVM instance

Perform the following steps to launch an RT-KVM instance on a real-time enabled Compute node:

  1. Create an RT-KVM flavor on the overcloud:

    # openstack flavor create  r1.small 99 4096 20 4
    # openstack flavor set --property hw:cpu_policy=dedicated 99
    # openstack flavor set --property hw:cpu_realtime=yes 99
    # openstack flavor set --property hw:mem_page_size=1GB 99
    # openstack flavor set --property hw:cpu_realtime_mask="^0-1" 99
    # openstack flavor set --property hw:cpu_emulator_threads=isolate 99
  2. Launch an RT-KVM instance:

    # openstack server create  --image <rhel> --flavor r1.small --nic net-id=<dpdk-net> test-rt
  3. To verify that the instance uses the assigned emulator threads, run the following command:

    # virsh dumpxml <instance-id> | grep vcpu -A1
    <vcpu placement='static'>4</vcpu>
    <cputune>
      <vcpupin vcpu='0' cpuset='1'/>
      <vcpupin vcpu='1' cpuset='3'/>
      <vcpupin vcpu='2' cpuset='5'/>
      <vcpupin vcpu='3' cpuset='7'/>
      <emulatorpin cpuset='0-1'/>
      <vcpusched vcpus='2-3' scheduler='fifo'
      priority='1'/>
    </cputune>

9.3. Trusted Virtual Functions

You can configure trust between physical functions (PFs) and virtual functions (VFs), so that VFs can perform privileged actions, such as enabling promiscuous mode, or modifying a hardware address.

9.3.1. Configuring trust between virtual and physical functions

Prerequisites
  • An operational installation of Red Hat OpenStack Platform including director
Procedure

Complete the following steps to configure and deploy the overcloud with trust between physical and virtual functions:

  1. Add the NeutronPhysicalDevMappings parameter in the parameter_defaults section to link between the logical network name and the physical interface.

    parameter_defaults:
      NeutronPhysicalDevMappings:
        - sriov2:p5p2
  2. Add the new property, trusted, to the SR-IOV parameters.

    parameter_defaults:
      NeutronPhysicalDevMappings:
        - sriov2:p5p2
      NovaPCIPassthrough:
        - devname: "p5p2"
          physical_network: "sriov2"
          trusted: "true"
    Note

    You must include double quotation marks around the value "true".

    Important

    Complete the following step in trusted environments, as it allows trusted port binding by non-administrative accounts.

  3. Modify permissions to allow users to create and update port bindings.

    parameter_defaults:
      NeutronApiPolicies: {
        operator_create_binding_profile: { key: 'create_port:binding:profile', value: 'rule:admin_or_network_owner'},
        operator_get_binding_profile: { key: 'get_port:binding:profile', value: 'rule:admin_or_network_owner'},
        operator_update_binding_profile: { key: 'update_port:binding:profile', value: 'rule:admin_or_network_owner'}
      }

9.3.2. Utilizing trusted VF networks

  1. Create a network of type vlan.

    openstack network create trusted_vf_network  --provider-network-type vlan \
     --provider-segment 111 --provider-physical-network sriov2 \
     --external --disable-port-security
  2. Create a subnet.

    openstack subnet create --network trusted_vf_network \
      --ip-version 4 --subnet-range 192.168.111.0/24 --no-dhcp \
     subnet-trusted_vf_network
  3. Create a port. Set the vnic-type option to direct, and the binding-profile option to true.

    openstack port create --network sriov111 \
    --vnic-type direct --binding-profile trusted=true \
    sriov111_port_trusted
  4. Create an instance, and bind it to the previously-created trusted port.

    openstack server create --image rhel --flavor dpdk  --network internal --port trusted_vf_network_port_trusted --config-drive True --wait rhel-dpdk-sriov_trusted

Verify the trusted VF configuration on the hypervisor

  1. On the compute node that you created the instance, run the following command:
# ip link
7: p5p2: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 9000 qdisc mq state UP mode DEFAULT group default qlen 1000
    link/ether b4:96:91:1c:40:fa brd ff:ff:ff:ff:ff:ff
    vf 6 MAC fa:16:3e:b8:91:c2, vlan 111, spoof checking off, link-state auto, trust on, query_rss off
    vf 7 MAC fa:16:3e:84:cf:c8, vlan 111, spoof checking off, link-state auto, trust off, query_rss off
  1. Verify that the trust status of the VF is trust on. The example output contains details of an environment that contains two ports. Note that vf 6 contains the text trust on.

9.4. Configuring RX/TX queue size

You can experience packet loss at high packet rates above 3.5 million packets per second (mpps) for many reasons, such as:

  • a network interrupt
  • a SMI
  • packet processing latency in the Virtual Network Function

To prevent packet loss, increase the queue size from the default of 512 to a maximum of 1024.

Prerequisites

  • To configure RX, ensure that you have libvirt v2.3 and QEMU v2.7.
  • To configure TX, ensure that you have libvirt v3.7 and QEMU v2.10.

Procedure

  • To increase the RX and TX queue size, include the following lines to the parameter_defaults: section of a relevant director role. Here is an example with ComputeOvsDpdk role:

    parameter_defaults:
      ComputeOvsDpdkParameters:
        -NovaLibvirtRxQueueSize: 1024
        -NovaLibvirtTxQueueSize: 1024

Testing

  • You can observe the values for RX queue size and TX queue size in the nova.conf file:

    [libvirt]
    rx_queue_size=1024
    tx_queue_size=1024
  • You can check the values for RX queue size and TX queue size in the VM instance XML file generated by libvirt on the compute host.

    <devices>
       <interface type='vhostuser'>
         <mac address='56:48:4f:4d:5e:6f'/>
         <source type='unix' path='/tmp/vhost-user1' mode='server'/>
         <model type='virtio'/>
         <driver name='vhost' rx_queue_size='1024'   tx_queue_size='1024' />
         <address type='pci' domain='0x0000' bus='0x00' slot='0x10' function='0x0'/>
       </interface>
    </devices>

    To verify the values for RX queue size and TX queue size, use the following command on a KVM host:

    $ virsh dumpxml <vm name> | grep queue_size
  • You can check for improved performance, such as 3.8 mpps/core at 0 frame loss.

9.5. Configuring a NUMA-aware vSwitch

Important

This feature is available in this release as a Technology Preview, and therefore is not fully supported by Red Hat. It should only be used for testing, and should not be deployed in a production environment. For more information about Technology Preview features, see Scope of Coverage Details.

Before you implement a NUMA-aware vSwitch, examine the following components of your hardware configuration:

  • The number of physical networks.
  • The placement of PCI cards.
  • The physical architecture of the servers.

Memory-mapped I/O (MMIO) devices, such as PCIe NICs, are associated with specific NUMA nodes. When a VM and the NIC are on different NUMA nodes, there is a significant decrease in performance. To increase performance, align PCIe NIC placement and instance processing on the same NUMA node.

Use this feature to ensure that instances that share a physical network are located on the same NUMA node. To optimize datacenter hardware, you can leverage load-sharing VMs by using multiple networks, different network types, or bonding.

Important

To architect NUMA-node load sharing and network access correctly, you must understand the mapping of the PCIe slot and the NUMA node. For detailed information on your specific hardware, refer to your vendor’s documentation.

To prevent a cross-NUMA configuration, place the VM on the correct NUMA node, by providing the location of the NIC to Nova.

Prerequisites

  • You have enabled the filter “NUMATopologyFilter”

Procedure

  • Set a new NeutronPhysnetNUMANodesMapping parameter to map the physical network to the NUMA node that you associate with the physical network.
  • If you use tunnels, such as VxLAN or GRE, you must also set the NeutronTunnelNUMANodes parameter.

    parameter_defaults:
      NeutronPhysnetNUMANodesMapping: {<physnet_name>: [<NUMA_NODE>]}
      NeutronTunnelNUMANodes: <NUMA_NODE>,<NUMA_NODE>

Here is an example with two physical networks tunneled to NUMA node 0:

  • one project network associated with NUMA node 0
  • one management network without any affinity

    parameter_defaults:
      NeutronBridgeMappings:
        - tenant:br-link0
      NeutronPhysnetNUMANodesMapping: {tenant: [1], mgmt: [0,1]}
      NeutronTunnelNUMANodes: 0

Testing

  • Observe the configuration in the file /var/lib/config-data/puppet-generated/nova_libvirt/etc/nova/nova.conf

    [neutron_physnet_tenant]
    numa_nodes=1
    [neutron_tunnel]
    numa_nodes=1
  • Confirm the new configuration with the lscpu command:

    $ lscpu
  • Launch a VM, with the NIC attached to the appropriate network

9.6. Configuring Quality of Service (QoS) in an NFVi environment

For details on Configuring QoS, see Configuring Quality-of-Service (QoS) policies. Support is limited to QoS rule type bandwidth-limit on SR-IOV and OVS-DPDK egress interfaces.

Chapter 10. Example: Configuring OVS-DPDK and SR-IOV with VXLAN tunnelling

This section describes how to deploy Compute nodes with both OVS-DPDK and SR-IOV interfaces. The cluster includes ML2/OVS and VXLAN tunnelling.

Important

You must determine the best values for the OVS-DPDK parameters that you set in the network-environment.yaml file to optimize your OpenStack network for OVS-DPDK. For details, see: Deriving DPDK parameters with workflows.

10.1. Configuring roles data

Red Hat OpenStack Platform provides a set of default roles in the roles_data.yaml file. You can create your own roles_data.yaml file to support the roles you require.

For the purposes of this example, the ComputeOvsDpdkSriov role is created. For information on creating roles in Red Hat OpenStack Platform, see Advanced Overcloud Customization. For details on the specific role used for this example, see roles_data.yaml.

10.2. Configuring OVS-DPDK parameters

Important

You must determine the best values for the OVS-DPDK parameters that you set in the network-environment.yaml file to optimize your OpenStack network for OVS-DPDK. For details, see Deriving DPDK parameters with workflows.

  1. Add the custom resources for OVS-DPDK under resource_registry:

      resource_registry:
        # Specify the relative/absolute path to the config files you want to use for override the default.
        OS::TripleO::ComputeOvsDpdkSriov::Net::SoftwareConfig: nic-configs/computeovsdpdksriov.yaml
        OS::TripleO::Controller::Net::SoftwareConfig: nic-configs/controller.yaml
  2. Under parameter_defaults, set the tunnel type to vxlan, and the network type to vxlan,vlan:

    NeutronTunnelTypes: 'vxlan'
    NeutronNetworkType: 'vxlan,vlan'
  3. Under parameters_defaults, set the bridge mapping:

    # The OVS logical->physical bridge mappings to use.
    NeutronBridgeMappings:
      - dpdk-mgmt:br-link0
  4. Under parameter_defaults, set the role-specific parameters for the ComputeOvsDpdkSriov role:

      ##########################
      # OVS DPDK configuration #
      ##########################
      ComputeOvsDpdkSriovParameters:
        KernelArgs: "default_hugepagesz=1GB hugepagesz=1G hugepages=32 iommu=pt intel_iommu=on isolcpus=2-19,22-39"
        TunedProfileName: "cpu-partitioning"
        IsolCpusList: "2-19,22-39"
        NovaComputeCpuDedicatedSet: ['4-19,24-39']
        NovaReservedHostMemory: 4096
        OvsDpdkSocketMemory: "3072,1024"
        OvsDpdkMemoryChannels: "4"
        OvsDpdkCoreList: "0,20,1,21"
        OvsPmdCoreList: "2,22,3,23"
        NovaComputeCpuSharedSet: [0,20,1,21]
        NovaLibvirtRxQueueSize: 1024
        NovaLibvirtTxQueueSize: 1024
    Note

    To prevent failures during guest creation, assign at least one CPU with sibling thread on each NUMA node. In the example, the values for the OvsPmdCoreList parameter denote cores 2 and 22 from NUMA 0, and cores 3 and 23 from NUMA 1.

    Note

    These huge pages are consumed by the virtual machines, and also by OVS-DPDK using the OvsDpdkSocketMemory parameter as shown in this procedure. The number of huge pages available for the virtual machines is the boot parameter minus the OvsDpdkSocketMemory.

    You must also add hw:mem_page_size=1GB to the flavor you associate with the DPDK instance.

    Note

    OvsDPDKCoreList and OvsDpdkMemoryChannels are the required settings for this procedure. For optimum operation, ensure you deploy DPDK with appropriate parameters and values.

  5. Configure the role-specific parameters for SR-IOV:

      NovaPCIPassthrough:
        - devname: "p7p3"
          trusted: "true"
          physical_network: "sriov-1"
        - devname: "p7p4"
          trusted: "true"
          physical_network: "sriov-2"

10.3. Configuring the controller node

  1. Create the control-plane Linux bond for an isolated network.

      - type: linux_bond
        name: bond_api
        bonding_options: "mode=active-backup"
        use_dhcp: false
        dns_servers:
          get_param: DnsServers
        members:
        - type: interface
          name: nic2
          primary: true
  2. Assign VLANs to this Linux bond.

      - type: vlan
        vlan_id:
          get_param: InternalApiNetworkVlanID
        device: bond_api
        addresses:
        - ip_netmask:
            get_param: InternalApiIpSubnet
    
      - type: vlan
        vlan_id:
          get_param: StorageNetworkVlanID
        device: bond_api
        addresses:
        - ip_netmask:
            get_param: StorageIpSubnet
    
      - type: vlan
        vlan_id:
          get_param: StorageMgmtNetworkVlanID
        device: bond_api
        addresses:
        - ip_netmask:
            get_param: StorageMgmtIpSubnet
    
      - type: vlan
        vlan_id:
          get_param: ExternalNetworkVlanID
        device: bond_api
        addresses:
        - ip_netmask:
            get_param: ExternalIpSubnet
        routes:
        - default: true
          next_hop:
            get_param: ExternalInterfaceDefaultRoute
  3. Create the OVS bridge to access neutron-dhcp-agent and neutron-metadata-agent services.

      - type: ovs_bridge
        name: br-link0
        use_dhcp: false
        mtu: 9000
        members:
        - type: interface
          name: nic3
          mtu: 9000
        - type: vlan
          vlan_id:
            get_param: TenantNetworkVlanID
          mtu: 9000
          addresses:
          - ip_netmask:
              get_param: TenantIpSubnet

10.4. Configuring the Compute node for DPDK and SR-IOV

Create the computeovsdpdksriov.yaml file from the default compute.yaml file, and make the following changes:

  1. Create the control-plane Linux bond for an isolated network.

      - type: linux_bond
        name: bond_api
        bonding_options: "mode=active-backup"
        use_dhcp: false
        dns_servers:
          get_param: DnsServers
        members:
        - type: interface
          name: nic3
          primary: true
        - type: interface
          name: nic4
  2. Assign VLANs to this Linux bond.

      - type: vlan
        vlan_id:
          get_param: InternalApiNetworkVlanID
        device: bond_api
        addresses:
        - ip_netmask:
            get_param: InternalApiIpSubnet
    
      - type: vlan
        vlan_id:
          get_param: StorageNetworkVlanID
        device: bond_api
        addresses:
        - ip_netmask:
            get_param: StorageIpSubnet
  3. Set a bridge with a DPDK port to link to the controller.

      - type: ovs_user_bridge
        name: br-link0
        use_dhcp: false
        ovs_extra:
          - str_replace:
              template: set port br-link0 tag=_VLAN_TAG_
              params:
                _VLAN_TAG_:
                   get_param: TenantNetworkVlanID
        addresses:
          - ip_netmask:
              get_param: TenantIpSubnet
        members:
          - type: ovs_dpdk_bond
            name: dpdkbond0
            mtu: 9000
            rx_queue: 2
            members:
              - type: ovs_dpdk_port
                name: dpdk0
                members:
                  - type: interface
                    name: nic7
              - type: ovs_dpdk_port
                name: dpdk1
                members:
                  - type: interface
                    name: nic8
    Note

    To include multiple DPDK devices, repeat the type code section for each DPDK device that you want to add.

    Note

    When using OVS-DPDK, all bridges on the same Compute node must be of type ovs_user_bridge. Red Hat OpenStack Platform does not support both ovs_bridge and ovs_user_bridge located on the same node.

10.5. Deploying the overcloud

  1. Run the overcloud_deploy.sh script:

Chapter 11. Upgrading Red Hat OpenStack platform with NFV

For more information about upgrading Red Hat OpenStack Platform (RHOSP) with OVS-DPDK configured, see Preparing network functions virtualization (NFV) in the Framework for Upgrades (13 to 16.1) Guide.

Chapter 12. NFV Performance

Red Hat OpenStack Platform director configures the Compute nodes to enforce resource partitioning and fine tuning to achieve line rate performance for the guest virtual network functions (VNFs). The key performance factors in the NFV use case are throughput, latency, and jitter.

You can enable high-performance packet switching between physical NICs and virtual machines using data plane development kit (DPDK) accelerated virtual machines. OVS 2.10 embeds support for DPDK 17 and includes support for vhost-user multiqueue, allowing scalable performance. OVS-DPDK provides line-rate performance for guest VNFs.

Single root I/O virtualization (SR-IOV) networking provides enhanced performance, including improved throughput for specific networks and virtual machines.

Other important features for performance tuning include huge pages, NUMA alignment, host isolation, and CPU pinning. VNF flavors require huge pages and emulator thread isolation for better performance. Host isolation and CPU pinning improve NFV performance and prevent spurious packet loss.

For a high-level introduction to CPUs and NUMA topology, see: NFV Performance Considerations and Configure Emulator Threads to run on a Dedicated Physical CPU.

Chapter 13. Finding more information

The following table includes additional Red Hat documentation for reference:

The Red Hat OpenStack Platform documentation suite can be found here: Red Hat OpenStack Platform Documentation Suite

Table 13.1. List of Available Documentation

ComponentReference

Red Hat Enterprise Linux

Red Hat OpenStack Platform is supported on Red Hat Enterprise Linux 8.0. For information on installing Red Hat Enterprise Linux, see the corresponding installation guide at: Red Hat Enterprise Linux Documentation Suite.

Red Hat OpenStack Platform

To install OpenStack components and their dependencies, use the Red Hat OpenStack Platform director. The director uses a basic OpenStack installation as the undercloud to install, configure, and manage the OpenStack nodes in the final overcloud. You need one extra host machine for the installation of the undercloud, in addition to the environment necessary for the deployed overcloud. For detailed instructions, see Red Hat OpenStack Platform Director Installation and Usage.

For information on configuring advanced features for a Red Hat OpenStack Platform enterprise environment using the Red Hat OpenStack Platform director such as network isolation, storage configuration, SSL communication, and general configuration method, see Advanced Overcloud Customization.

NFV Documentation

For a high level overview of the NFV concepts, see the Network Functions Virtualization Product Guide.

Appendix A. Sample DPDK SRIOV YAML files

This section provides sample yaml files as a reference to add single root I/O virtualization (SR-IOV) and Data Plane Development Kit (DPDK) interfaces on the same compute node.

Note

These templates are from a fully-configured environment, and include parameters unrelated to NFV, that might not apply to your deployment.

A.1. Sample VXLAN DPDK SRIOV YAML files

A.1.1. roles_data.yaml

  1. Run the openstack overcloud roles generate command to generate the roles_data.yaml file. Include role names in the command according to the roles that you want to deploy in your environment, such as Controller, ComputeSriov, ComputeOvsDpdkRT, ComputeOvsDpdkSriov, or other roles. For example, to generate a roles_data.yaml file that contains the roles Controller and ComputeOvsDpdkSriov, run the following command:
 $ openstack overcloud roles generate -o roles_data.yaml Controller ComputeOvsDpdkSriov
###############################################################################
# File generated by TripleO
###############################################################################
###############################################################################
# Role: Controller                                                            #
###############################################################################
- name: Controller
  description: |
    Controller role that has all the controller services loaded and handles
    Database, Messaging and Network functions.
  CountDefault: 1
  tags:
    - primary
    - controller
  networks:
    - External
    - InternalApi
    - Storage
    - StorageMgmt
    - Tenant
  # For systems with both IPv4 and IPv6, you may specify a gateway network for
  # each, such as ['ControlPlane', 'External']
  default_route_networks: ['External']
  HostnameFormatDefault: '%stackname%-controller-%index%'
  # Deprecated & backward-compatible values (FIXME: Make parameters consistent)
  # Set uses_deprecated_params to True if any deprecated params are used.
  uses_deprecated_params: True
  deprecated_param_extraconfig: 'controllerExtraConfig'
  deprecated_param_flavor: 'OvercloudControlFlavor'
  deprecated_param_image: 'controllerImage'
  deprecated_nic_config_name: 'controller.yaml'
  ServicesDefault:
    - OS::TripleO::Services::Aide
    - OS::TripleO::Services::AodhApi
    - OS::TripleO::Services::AodhEvaluator
    - OS::TripleO::Services::AodhListener
    - OS::TripleO::Services::AodhNotifier
    - OS::TripleO::Services::AuditD
    - OS::TripleO::Services::BarbicanApi
    - OS::TripleO::Services::BarbicanBackendSimpleCrypto
    - OS::TripleO::Services::BarbicanBackendDogtag
    - OS::TripleO::Services::BarbicanBackendKmip
    - OS::TripleO::Services::BarbicanBackendPkcs11Crypto
    - OS::TripleO::Services::CACerts
    - OS::TripleO::Services::CeilometerAgentCentral
    - OS::TripleO::Services::CeilometerAgentNotification
    - OS::TripleO::Services::CephExternal
    - OS::TripleO::Services::CephMds
    - OS::TripleO::Services::CephMgr
    - OS::TripleO::Services::CephMon
    - OS::TripleO::Services::CephRbdMirror
    - OS::TripleO::Services::CephRgw
    - OS::TripleO::Services::CertmongerUser
    - OS::TripleO::Services::CinderApi
    - OS::TripleO::Services::CinderBackendDellPs
    - OS::TripleO::Services::CinderBackendDellSc
    - OS::TripleO::Services::CinderBackendDellEMCUnity
    - OS::TripleO::Services::CinderBackendDellEMCVMAXISCSI
    - OS::TripleO::Services::CinderBackendDellEMCVNX
    - OS::TripleO::Services::CinderBackendDellEMCXTREMIOISCSI
    - OS::TripleO::Services::CinderBackendNetApp
    - OS::TripleO::Services::CinderBackendScaleIO
    - OS::TripleO::Services::CinderBackendVRTSHyperScale
    - OS::TripleO::Services::CinderBackendNVMeOF
    - OS::TripleO::Services::CinderBackup
    - OS::TripleO::Services::CinderHPELeftHandISCSI
    - OS::TripleO::Services::CinderScheduler
    - OS::TripleO::Services::CinderVolume
    - OS::TripleO::Services::Clustercheck
    - OS::TripleO::Services::Collectd
    - OS::TripleO::Services::Congress
    - OS::TripleO::Services::ContainerImagePrepare
    - OS::TripleO::Services::DesignateApi
    - OS::TripleO::Services::DesignateCentral
    - OS::TripleO::Services::DesignateProducer
    - OS::TripleO::Services::DesignateWorker
    - OS::TripleO::Services::DesignateMDNS
    - OS::TripleO::Services::DesignateSink
    - OS::TripleO::Services::Docker
    - OS::TripleO::Services::Ec2Api
    - OS::TripleO::Services::Etcd
    - OS::TripleO::Services::ExternalSwiftProxy
    - OS::TripleO::Services::Fluentd
    - OS::TripleO::Services::GlanceApi
    - OS::TripleO::Services::GlanceRegistry
    - OS::TripleO::Services::GnocchiApi
    - OS::TripleO::Services::GnocchiMetricd
    - OS::TripleO::Services::GnocchiStatsd
    - OS::TripleO::Services::HAproxy
    - OS::TripleO::Services::HeatApi
    - OS::TripleO::Services::HeatApiCloudwatch
    - OS::TripleO::Services::HeatApiCfn
    - OS::TripleO::Services::HeatEngine
    - OS::TripleO::Services::Horizon
    - OS::TripleO::Services::Ipsec
    - OS::TripleO::Services::IronicApi
    - OS::TripleO::Services::IronicConductor
    - OS::TripleO::Services::IronicInspector
    - OS::TripleO::Services::IronicPxe
    - OS::TripleO::Services::IronicNeutronAgent
    - OS::TripleO::Services::Iscsid
    - OS::TripleO::Services::Keepalived
    - OS::TripleO::Services::Kernel
    - OS::TripleO::Services::Keystone
    - OS::TripleO::Services::LoginDefs
    - OS::TripleO::Services::ManilaApi
    - OS::TripleO::Services::ManilaBackendCephFs
    - OS::TripleO::Services::ManilaBackendIsilon
    - OS::TripleO::Services::ManilaBackendNetapp
    - OS::TripleO::Services::ManilaBackendUnity
    - OS::TripleO::Services::ManilaBackendVNX
    - OS::TripleO::Services::ManilaBackendVMAX
    - OS::TripleO::Services::ManilaScheduler
    - OS::TripleO::Services::ManilaShare
    - OS::TripleO::Services::Memcached
    - OS::TripleO::Services::MetricsQdr
    - OS::TripleO::Services::MistralApi
    - OS::TripleO::Services::MistralEngine
    - OS::TripleO::Services::MistralExecutor
    - OS::TripleO::Services::MistralEventEngine
    - OS::TripleO::Services::MongoDb
    - OS::TripleO::Services::MySQL
    - OS::TripleO::Services::MySQLClient
    - OS::TripleO::Services::NeutronApi
    - OS::TripleO::Services::NeutronBgpVpnApi
    - OS::TripleO::Services::NeutronSfcApi
    - OS::TripleO::Services::NeutronCorePlugin
    - OS::TripleO::Services::NeutronDhcpAgent
    - OS::TripleO::Services::NeutronL2gwAgent
    - OS::TripleO::Services::NeutronL2gwApi
    - OS::TripleO::Services::NeutronL3Agent
    - OS::TripleO::Services::NeutronLbaasv2Agent
    - OS::TripleO::Services::NeutronLbaasv2Api
    - OS::TripleO::Services::NeutronLinuxbridgeAgent
    - OS::TripleO::Services::NeutronMetadataAgent
    - OS::TripleO::Services::NeutronML2FujitsuCfab
    - OS::TripleO::Services::NeutronML2FujitsuFossw
    - OS::TripleO::Services::NeutronOvsAgent
    - OS::TripleO::Services::NeutronVppAgent
    - OS::TripleO::Services::NovaApi
    - OS::TripleO::Services::NovaConductor
    - OS::TripleO::Services::NovaConsoleauth
    - OS::TripleO::Services::NovaIronic
    - OS::TripleO::Services::NovaMetadata
    - OS::TripleO::Services::NovaPlacement
    - OS::TripleO::Services::NovaScheduler
    - OS::TripleO::Services::NovaVncProxy
    - OS::TripleO::Services::Ntp
    - OS::TripleO::Services::ContainersLogrotateCrond
    - OS::TripleO::Services::OctaviaApi
    - OS::TripleO::Services::OctaviaDeploymentConfig
    - OS::TripleO::Services::OctaviaHealthManager
    - OS::TripleO::Services::OctaviaHousekeeping
    - OS::TripleO::Services::OctaviaWorker
    - OS::TripleO::Services::OpenDaylightApi
    - OS::TripleO::Services::OpenDaylightOvs
    - OS::TripleO::Services::OVNDBs
    - OS::TripleO::Services::OVNController
    - OS::TripleO::Services::Pacemaker
    - OS::TripleO::Services::PankoApi
    - OS::TripleO::Services::OsloMessagingRpc
    - OS::TripleO::Services::OsloMessagingNotify
    - OS::TripleO::Services::Redis
    - OS::TripleO::Services::Rhsm
    - OS::TripleO::Services::RsyslogSidecar
    - OS::TripleO::Services::Securetty
    - OS::TripleO::Services::SensuClient
    - OS::TripleO::Services::SkydiveAgent
    - OS::TripleO::Services::SkydiveAnalyzer
    - OS::TripleO::Services::Snmp
    - OS::TripleO::Services::Sshd
    - OS::TripleO::Services::SwiftProxy
    - OS::TripleO::Services::SwiftDispersion
    - OS::TripleO::Services::SwiftRingBuilder
    - OS::TripleO::Services::SwiftStorage
    - OS::TripleO::Services::Tacker
    - OS::TripleO::Services::Timezone
    - OS::TripleO::Services::TripleoFirewall
    - OS::TripleO::Services::TripleoPackages
    - OS::TripleO::Services::Tuned
    - OS::TripleO::Services::Vpp
    - OS::TripleO::Services::Zaqar
    - OS::TripleO::Services::Ptp
    - OS::TripleO::Services::Xinetd
###############################################################################
# Role: ComputeOvsDpdkSriov                                                   #
###############################################################################
- name: ComputeOvsDpdkSriov
  description: |
    Compute OvS DPDK Role
  CountDefault: 1
  networks:
    - InternalApi
    - Tenant
    - Storage
  RoleParametersDefault:
    VhostuserSocketGroup: "hugetlbfs"
    TunedProfileName: "cpu-partitioning"
  ServicesDefault:
    - OS::TripleO::Services::Aide
    - OS::TripleO::Services::AuditD
    - OS::TripleO::Services::BootParams
    - OS::TripleO::Services::CACerts
    - OS::TripleO::Services::CephClient
    - OS::TripleO::Services::CephExternal
    - OS::TripleO::Services::CertmongerUser
    - OS::TripleO::Services::Collectd
    - OS::TripleO::Services::ComputeCeilometerAgent
    - OS::TripleO::Services::ComputeNeutronCorePlugin
    - OS::TripleO::Services::ComputeNeutronL3Agent
    - OS::TripleO::Services::ComputeNeutronMetadataAgent
    - OS::TripleO::Services::ComputeNeutronOvsDpdk
    - OS::TripleO::Services::NeutronSriovAgent
    - OS::TripleO::Services::NeutronSriovHostConfig
    - OS::TripleO::Services::Docker
    - OS::TripleO::Services::Fluentd
    - OS::TripleO::Services::Ipsec
    - OS::TripleO::Services::Iscsid
    - OS::TripleO::Services::Kernel
    - OS::TripleO::Services::LoginDefs
    - OS::TripleO::Services::MetricsQdr
    - OS::TripleO::Services::MySQLClient
    - OS::TripleO::Services::NeutronBgpVpnBagpipe
    - OS::TripleO::Services::NovaCompute
    - OS::TripleO::Services::NovaLibvirt
    - OS::TripleO::Services::NovaLibvirtGuests
    - OS::TripleO::Services::NovaMigrationTarget
    - OS::TripleO::Services::Ntp
    - OS::TripleO::Services::ContainersLogrotateCrond
    - OS::TripleO::Services::OpenDaylightOvs
    - OS::TripleO::Services::OVNMetadataAgent
    - OS::TripleO::Services::Rhsm
    - OS::TripleO::Services::RsyslogSidecar
    - OS::TripleO::Services::Securetty
    - OS::TripleO::Services::SensuClient
    - OS::TripleO::Services::SkydiveAgent
    - OS::TripleO::Services::Snmp
    - OS::TripleO::Services::Sshd
    - OS::TripleO::Services::Timezone
    - OS::TripleO::Services::TripleoFirewall
    - OS::TripleO::Services::TripleoPackages
    - OS::TripleO::Services::Ptp

A.1.2. network-environment-overrides.yaml

resource_registry:
  # Specify the relative/absolute path to the config files you want to use for override the default.
  OS::TripleO::ComputeOvsDpdkSriov::Net::SoftwareConfig: nic-configs/computeovsdpdksriov.yaml
  OS::TripleO::Controller::Net::SoftwareConfig: nic-configs/controller.yaml

# Customize all these values to match the local environment
parameter_defaults:
  # The tunnel type for the project network (vxlan or gre). Set to '' to disable tunneling.
  NeutronTunnelTypes: 'vxlan'
  # The project network type for Neutron (vlan or vxlan).
  NeutronNetworkType: 'vxlan,vlan'
  # The OVS logical->physical bridge mappings to use.
  NeutronBridgeMappings: 'access:br-access,dpdk-mgmt:br-link0'
  # The Neutron ML2 and OpenVSwitch vlan mapping range to support.
  NeutronNetworkVLANRanges: 'access:423:423,dpdk-mgmt:134:137,sriov-1:138:139,sriov-2:138:139'
  # Define the DNS servers (maximum 2) for the overcloud nodes
  DnsServers: ["10.46.0.31","10.46.0.32"]
  # Nova flavor to use.
  OvercloudControllerFlavor: controller
  OvercloudComputeOvsDpdkSriovFlavor: computeovsdpdksriov
  # Number of nodes to deploy.
  ControllerCount: 3
  ComputeOvsDpdkSriovCount: 2
  # NTP server configuration.
  NtpServer: ['clock.redhat.com']
  # MTU global configuration
  NeutronGlobalPhysnetMtu: 9000
  # Configure the classname of the firewall driver to use for implementing security groups.
  NeutronOVSFirewallDriver: openvswitch
  SshServerOptions:
    UseDns: 'no'
  # Enable log level DEBUG for supported components
  # Debug: True

  ControllerHostnameFormat: 'controller-%index%'
  ControllerSchedulerHints:
    'capabilities:node': 'controller-%index%'
  ComputeOvsDpdkSriovHostnameFormat: 'computeovsdpdksriov-%index%'
  ComputeOvsDpdkSriovSchedulerHints:
    'capabilities:node': 'computeovsdpdksriov-%index%'

  # From Rocky live migration with NumaTopologyFilter disabled by default
  # https://bugs.launchpad.net/nova/+bug/1289064
  NovaEnableNUMALiveMigration: true

  ##########################
  # OVS DPDK configuration #
  ##########################

  # In the future, most parameters will be derived by mistral plan.
  # Currently mistral derive parameters is blocked:
  # https://bugzilla.redhat.com/show_bug.cgi?id=1777841
  # https://bugzilla.redhat.com/show_bug.cgi?id=1777844
  ComputeOvsDpdkSriovParameters:
    KernelArgs: "default_hugepagesz=1GB hugepagesz=1G hugepages=64 iommu=pt intel_iommu=on isolcpus=2-19,22-39"
    TunedProfileName: "cpu-partitioning"
    IsolCpusList: "2-19,22-39"
    NovaComputeCpuDedicatedSet: ['2-10,12-17,19,22-30,32-37,39']
    NovaReservedHostMemory: 4096
    OvsDpdkSocketMemory: "1024,3072"
    OvsDpdkMemoryChannels: "4"
    OvsDpdkCoreList: "0,20,1,21"
    OvsPmdCoreList: "11,18,31,38"
    NovaComputeCpuSharedSet: [0,20,1,21]
    # When using NIC partioning on SR-IOV enabled setups, 'derive_pci_passthrough_whitelist.py'
    # script will be executed which will override NovaPCIPassthrough.
    # No option to disable as of now - https://bugzilla.redhat.com/show_bug.cgi?id=1774403
    NovaPCIPassthrough:
      - devname: "enp6s0f2"
        trusted: "true"
        physical_network: "sriov-1"
      - devname: "enp6s0f3"
        trusted: "true"
        physical_network: "sriov-2"

    # NUMA aware vswitch
    NeutronPhysnetNUMANodesMapping: {dpdk-mgmt: [0]}
    NeutronTunnelNUMANodes: [0]
    NeutronPhysicalDevMappings:
    - sriov1:enp6s0f2
    - sriov2:enp6s0f3

  ############################
  #  Scheduler configuration #
  ############################
  NovaSchedulerDefaultFilters:
    - "RetryFilter"
    - "AvailabilityZoneFilter"
    - "ComputeFilter"
    - "ComputeCapabilitiesFilter"
    - "ImagePropertiesFilter"
    - "ServerGroupAntiAffinityFilter"
    - "ServerGroupAffinityFilter"
    - "PciPassthroughFilter"
    - "NUMATopologyFilter"
    - "AggregateInstanceExtraSpecsFilter"

A.1.3. controller.yaml

heat_template_version: rocky
description: >
  Software Config to drive os-net-config to configure VLANs for the controller role.
parameters:
  ControlPlaneIp:
    default: ''
    description: IP address/subnet on the ctlplane network
    type: string
  ExternalIpSubnet:
    default: ''
    description: IP address/subnet on the external network
    type: string
  ExternalInterfaceRoutes:
    default: []
    description: >
      Routes for the external network traffic. JSON route e.g. [{'destination':'10.0.0.0/16', 'nexthop':'10.0.0.1'}] Unless
      the default is changed, the parameter is automatically resolved from the subnet host_routes attribute.
    type: json
  InternalApiIpSubnet:
    default: ''
    description: IP address/subnet on the internal_api network
    type: string
  InternalApiInterfaceRoutes:
    default: []
    description: >
      Routes for the internal_api network traffic. JSON route e.g. [{'destination':'10.0.0.0/16', 'nexthop':'10.0.0.1'}] Unless
      the default is changed, the parameter is automatically resolved from the subnet host_routes attribute.
    type: json
  StorageIpSubnet:
    default: ''
    description: IP address/subnet on the storage network
    type: string
  StorageInterfaceRoutes:
    default: []
    description: >
      Routes for the storage network traffic. JSON route e.g. [{'destination':'10.0.0.0/16', 'nexthop':'10.0.0.1'}] Unless
      the default is changed, the parameter is automatically resolved from the subnet host_routes attribute.
    type: json
  StorageMgmtIpSubnet:
    default: ''
    description: IP address/subnet on the storage_mgmt network
    type: string
  StorageMgmtInterfaceRoutes:
    default: []
    description: >
      Routes for the storage_mgmt network traffic. JSON route e.g. [{'destination':'10.0.0.0/16', 'nexthop':'10.0.0.1'}] Unless
      the default is changed, the parameter is automatically resolved from the subnet host_routes attribute.
    type: json
  TenantIpSubnet:
    default: ''
    description: IP address/subnet on the tenant network
    type: string
  TenantInterfaceRoutes:
    default: []
    description: >
      Routes for the tenant network traffic. JSON route e.g. [{'destination':'10.0.0.0/16', 'nexthop':'10.0.0.1'}] Unless
      the default is changed, the parameter is automatically resolved from the subnet host_routes attribute.
    type: json
  ManagementIpSubnet: # Only populated when including environments/network-management.yaml
    default: ''
    description: IP address/subnet on the management network
    type: string
  ManagementInterfaceRoutes:
    default: []
    description: >
      Routes for the management network traffic. JSON route e.g. [{'destination':'10.0.0.0/16', 'nexthop':'10.0.0.1'}] Unless
      the default is changed, the parameter is automatically resolved from the subnet host_routes attribute.
    type: json
  BondInterfaceOvsOptions:
    default: bond_mode=active-backup
    description: >-
      The ovs_options string for the bond interface. Set things like lacp=active and/or bond_mode=balance-slb using this option.
    type: string
  ExternalNetworkVlanID:
    default: 10
    description: Vlan ID for the external network traffic.
    type: number
  InternalApiNetworkVlanID:
    default: 20
    description: Vlan ID for the internal_api network traffic.
    type: number
  StorageNetworkVlanID:
    default: 30
    description: Vlan ID for the storage network traffic.
    type: number
  StorageMgmtNetworkVlanID:
    default: 40
    description: Vlan ID for the storage_mgmt network traffic.
    type: number
  TenantNetworkVlanID:
    default: 50
    description: Vlan ID for the tenant network traffic.
    type: number
  ManagementNetworkVlanID:
    default: 60
    description: Vlan ID for the management network traffic.
    type: number
  ExternalInterfaceDefaultRoute:
    default: 10.0.0.1
    description: default route for the external network
    type: string
  ControlPlaneSubnetCidr:
    default: ''
    description: >
      The subnet CIDR of the control plane network. (The parameter is automatically resolved from the ctlplane subnet's cidr
      attribute.)
    type: string
  ControlPlaneDefaultRoute:
    default: ''
    description: >-
      The default route of the control plane network. (The parameter is automatically resolved from the ctlplane subnet's
      gateway_ip attribute.)
    type: string
  DnsServers: # Override this via parameter_defaults
    default: []
    description: >
      DNS servers to use for the Overcloud (2 max for some implementations). If not set the nameservers configured in the
      ctlplane subnet's dns_nameservers attribute will be used.
    type: comma_delimited_list
  EC2MetadataIp:
    default: ''
    description: >-
      The IP address of the EC2 metadata server. (The parameter is automatically resolved from the ctlplane subnet's host_routes
      attribute.)
    type: string
  ControlPlaneStaticRoutes:
    default: []
    description: >
      Routes for the ctlplane network traffic. JSON route e.g. [{'destination':'10.0.0.0/16', 'nexthop':'10.0.0.1'}] Unless
      the default is changed, the parameter is automatically resolved from the subnet host_routes attribute.
    type: json
  ControlPlaneMtu:
    default: 1500
    description: >-
      The maximum transmission unit (MTU) size(in bytes) that is guaranteed to pass through the data path of the segments
      in the network. (The parameter is automatically resolved from the ctlplane network's mtu attribute.)
    type: number
  StorageMtu:
    default: 1500
    description: >-
      The maximum transmission unit (MTU) size(in bytes) that is guaranteed to pass through the data path of the segments
      in the Storage network.
    type: number
  StorageMgmtMtu:
    default: 1500
    description: >-
      The maximum transmission unit (MTU) size(in bytes) that is guaranteed to pass through the data path of the segments
      in the StorageMgmt network.
    type: number
  InternalApiMtu:
    default: 1500
    description: >-
      The maximum transmission unit (MTU) size(in bytes) that is guaranteed to pass through the data path of the segments
      in the InternalApi network.
    type: number
  TenantMtu:
    default: 1500
    description: >-
      The maximum transmission unit (MTU) size(in bytes) that is guaranteed to pass through the data path of the segments
      in the Tenant network.
    type: number
  ExternalMtu:
    default: 1500
    description: >-
      The maximum transmission unit (MTU) size(in bytes) that is guaranteed to pass through the data path of the segments
      in the External network.
    type: number
resources:
  OsNetConfigImpl:
    type: OS::Heat::SoftwareConfig
    properties:
      group: script
      config:
        str_replace:
          template:
            get_file: /usr/share/openstack-tripleo-heat-templates/network/scripts/run-os-net-config.sh
          params:
            $network_config:
              network_config:
              - type: interface
                name: nic1
                use_dhcp: false
                addresses:
                - ip_netmask:
                    list_join:
                    - /
                    - - get_param: ControlPlaneIp
                      - get_param: ControlPlaneSubnetCidr
                routes:
                - ip_netmask: 169.254.169.254/32
                  next_hop:
                    get_param: EC2MetadataIp

              - type: ovs_bridge
                name: br-link0
                use_dhcp: false
                mtu: 9000
                members:
                - type: interface
                  name: nic2
                  mtu: 9000

                - type: vlan
                  vlan_id:
                    get_param: TenantNetworkVlanID
                  mtu: 9000
                  addresses:
                  - ip_netmask:
                      get_param: TenantIpSubnet

                - type: vlan
                  vlan_id:
                    get_param: InternalApiNetworkVlanID
                  addresses:
                  - ip_netmask:
                      get_param: InternalApiIpSubnet

                - type: vlan
                  vlan_id:
                    get_param: StorageNetworkVlanID
                  addresses:
                  - ip_netmask:
                      get_param: StorageIpSubnet

                - type: vlan
                  vlan_id:
                    get_param: StorageMgmtNetworkVlanID
                  addresses:
                  - ip_netmask:
                      get_param: StorageMgmtIpSubnet

              - type: ovs_bridge
                name: br-access
                use_dhcp: false
                mtu: 9000
                members:
                - type: interface
                  name: nic3
                  mtu: 9000
                - type: vlan
                  vlan_id:
                    get_param: ExternalNetworkVlanID
                  mtu: 9000
                  addresses:
                  - ip_netmask:
                      get_param: ExternalIpSubnet
                  routes:
                  - default: true
                    next_hop:
                      get_param: ExternalInterfaceDefaultRoute
outputs:
  OS::stack_id:
    description: The OsNetConfigImpl resource.
    value:
      get_resource: OsNetConfigImpl

A.1.4. compute-ovs-dpdk.yaml

heat_template_version: rocky

description: >
  Software Config to drive os-net-config to configure VLANs for the
  compute role.

parameters:
  ControlPlaneIp:
    default: ''
    description: IP address/subnet on the ctlplane network
    type: string
  ExternalIpSubnet:
    default: ''
    description: IP address/subnet on the external network
    type: string
  ExternalInterfaceRoutes:
    default: []
    description: >
      Routes for the external network traffic.
      JSON route e.g. [{'destination':'10.0.0.0/16', 'nexthop':'10.0.0.1'}]
      Unless the default is changed, the parameter is automatically resolved
      from the subnet host_routes attribute.
    type: json
  InternalApiIpSubnet:
    default: ''
    description: IP address/subnet on the internal_api network
    type: string
  InternalApiInterfaceRoutes:
    default: []
    description: >
      Routes for the internal_api network traffic.
      JSON route e.g. [{'destination':'10.0.0.0/16', 'nexthop':'10.0.0.1'}]
      Unless the default is changed, the parameter is automatically resolved
      from the subnet host_routes attribute.
    type: json
  StorageIpSubnet:
    default: ''
    description: IP address/subnet on the storage network
    type: string
  StorageInterfaceRoutes:
    default: []
    description: >
      Routes for the storage network traffic.
      JSON route e.g. [{'destination':'10.0.0.0/16', 'nexthop':'10.0.0.1'}]
      Unless the default is changed, the parameter is automatically resolved
      from the subnet host_routes attribute.
    type: json
  StorageMgmtIpSubnet:
    default: ''
    description: IP address/subnet on the storage_mgmt network
    type: string
  StorageMgmtInterfaceRoutes:
    default: []
    description: >
      Routes for the storage_mgmt network traffic.
      JSON route e.g. [{'destination':'10.0.0.0/16', 'nexthop':'10.0.0.1'}]
      Unless the default is changed, the parameter is automatically resolved
      from the subnet host_routes attribute.
    type: json
  TenantIpSubnet:
    default: ''
    description: IP address/subnet on the tenant network
    type: string
  TenantInterfaceRoutes:
    default: []
    description: >
      Routes for the tenant network traffic.
      JSON route e.g. [{'destination':'10.0.0.0/16', 'nexthop':'10.0.0.1'}]
      Unless the default is changed, the parameter is automatically resolved
      from the subnet host_routes attribute.
    type: json
  ManagementIpSubnet: # Only populated when including environments/network-management.yaml
    default: ''
    description: IP address/subnet on the management network
    type: string
  ManagementInterfaceRoutes:
    default: []
    description: >
      Routes for the management network traffic.
      JSON route e.g. [{'destination':'10.0.0.0/16', 'nexthop':'10.0.0.1'}]
      Unless the default is changed, the parameter is automatically resolved
      from the subnet host_routes attribute.
    type: json
  BondInterfaceOvsOptions:
    default: 'bond_mode=active-backup'
    description: The ovs_options string for the bond interface. Set things like
                 lacp=active and/or bond_mode=balance-slb using this option.
    type: string
  ExternalNetworkVlanID:
    default: 10
    description: Vlan ID for the external network traffic.
    type: number
  InternalApiNetworkVlanID:
    default: 20
    description: Vlan ID for the internal_api network traffic.
    type: number
  StorageNetworkVlanID:
    default: 30
    description: Vlan ID for the storage network traffic.
    type: number
  StorageMgmtNetworkVlanID:
    default: 40
    description: Vlan ID for the storage_mgmt network traffic.
    type: number
  TenantNetworkVlanID:
    default: 50
    description: Vlan ID for the tenant network traffic.
    type: number
  ManagementNetworkVlanID:
    default: 60
    description: Vlan ID for the management network traffic.
    type: number
  ExternalInterfaceDefaultRoute:
    default: '10.0.0.1'
    description: default route for the external network
    type: string
  ControlPlaneSubnetCidr:
    default: ''
    description: >
      The subnet CIDR of the control plane network. (The parameter is
      automatically resolved from the ctlplane subnet's cidr attribute.)
    type: string
  ControlPlaneDefaultRoute:
    default: ''
    description: The default route of the control plane network. (The parameter
      is automatically resolved from the ctlplane subnet's gateway_ip attribute.)
    type: string
  DnsServers: # Override this via parameter_defaults
    default: []
    description: >
      DNS servers to use for the Overcloud (2 max for some implementations).
      If not set the nameservers configured in the ctlplane subnet's
      dns_nameservers attribute will be used.
    type: comma_delimited_list
  EC2MetadataIp:
    default: ''
    description: The IP address of the EC2 metadata server. (The parameter
      is automatically resolved from the ctlplane subnet's host_routes attribute.)
    type: string
  ControlPlaneStaticRoutes:
    default: []
    description: >
      Routes for the ctlplane network traffic. JSON route e.g. [{'destination':'10.0.0.0/16', 'nexthop':'10.0.0.1'}] Unless
      the default is changed, the parameter is automatically resolved from the subnet host_routes attribute.
    type: json
  ControlPlaneMtu:
    default: 1500
    description: >-
      The maximum transmission unit (MTU) size(in bytes) that is guaranteed to pass through the data path of the segments
      in the network. (The parameter is automatically resolved from the ctlplane network's mtu attribute.)
    type: number
  StorageMtu:
    default: 1500
    description: >-
      The maximum transmission unit (MTU) size(in bytes) that is guaranteed to pass through the data path of the segments
      in the Storage network.
    type: number
  InternalApiMtu:
    default: 1500
    description: >-
      The maximum transmission unit (MTU) size(in bytes) that is guaranteed to pass through the data path of the segments
      in the InternalApi network.
    type: number
  TenantMtu:
    default: 1500
    description: >-
      The maximum transmission unit (MTU) size(in bytes) that is guaranteed to pass through the data path of the segments
      in the Tenant network.
    type: number

resources:
  OsNetConfigImpl:
    type: OS::Heat::SoftwareConfig
    properties:
      group: script
      config:
        str_replace:
          template:
            get_file: /usr/share/openstack-tripleo-heat-templates/network/scripts/run-os-net-config.sh
          params:
            $network_config:
              network_config:
              - type: interface
                name: nic1
                use_dhcp: false
                defroute: false

              - type: interface
                name: nic2
                use_dhcp: false
                addresses:
                - ip_netmask:
                    list_join:
                    - /
                    - - get_param: ControlPlaneIp
                      - get_param: ControlPlaneSubnetCidr
                routes:
                - ip_netmask: 169.254.169.254/32
                  next_hop:
                    get_param: EC2MetadataIp
                - default: true
                  next_hop:
                    get_param: ControlPlaneDefaultRoute

              - type: linux_bond
                name: bond_api
                bonding_options: mode=active-backup
                use_dhcp: false
                dns_servers:
                  get_param: DnsServers
                members:
                - type: interface
                  name: nic3
                  primary: true
                - type: interface
                  name: nic4

              - type: vlan
                vlan_id:
                  get_param: InternalApiNetworkVlanID
                device: bond_api
                addresses:
                - ip_netmask:
                    get_param: InternalApiIpSubnet

              - type: vlan
                vlan_id:
                  get_param: StorageNetworkVlanID
                device: bond_api
                addresses:
                - ip_netmask:
                    get_param: StorageIpSubnet

              - type: ovs_user_bridge
                name: br-link0
                use_dhcp: false
                ovs_extra:
                - str_replace:
                    template: set port br-link0 tag=_VLAN_TAG_
                    params:
                      _VLAN_TAG_:
                        get_param: TenantNetworkVlanID
                addresses:
                - ip_netmask:
                    get_param: TenantIpSubnet
                members:
                - type: ovs_dpdk_bond
                  name: dpdkbond0
                  mtu: 9000
                  rx_queue: 2
                  members:
                  - type: ovs_dpdk_port
                    name: dpdk0
                    members:
                    - type: interface
                      name: nic7
                  - type: ovs_dpdk_port
                    name: dpdk1
                    members:
                    - type: interface
                      name: nic8

              - type: sriov_pf
                name: nic9
                mtu: 9000
                numvfs: 10
                use_dhcp: false
                defroute: false
                nm_controlled: true
                hotplug: true
                promisc: false

              - type: sriov_pf
                name: nic10
                mtu: 9000
                numvfs: 10
                use_dhcp: false
                defroute: false
                nm_controlled: true
                hotplug: true
                promisc: false
outputs:
  OS::stack_id:
    description: The OsNetConfigImpl resource.
    value:
      get_resource: OsNetConfigImpl

A.1.5. overcloud_deploy.sh

#!/bin/bash

THT_PATH='/home/stack/ospd-16-vxlan-dpdk-sriov-ctlplane-dataplane-bonding-hybrid'

openstack overcloud deploy \
--templates \
-e /usr/share/openstack-tripleo-heat-templates/environments/network-environment.yaml \
-e /usr/share/openstack-tripleo-heat-templates/environments/network-isolation.yaml \
-e /usr/share/openstack-tripleo-heat-templates/environments/services/neutron-ovs.yaml \
-e /usr/share/openstack-tripleo-heat-templates/environments/services/neutron-ovs-dpdk.yaml \
-e /usr/share/openstack-tripleo-heat-templates/environments/services/neutron-sriov.yaml \
-e /home/stack/containers-prepare-parameter.yaml \
-r $THT_PATH/roles_data.yaml \
-e $THT_PATH/network-environment-overrides.yaml \
-n $THT_PATH/network-data.yaml

Legal Notice

Copyright © 2021 Red Hat, Inc.
The text of and illustrations in this document are licensed by Red Hat under a Creative Commons Attribution–Share Alike 3.0 Unported license ("CC-BY-SA"). An explanation of CC-BY-SA is available at http://creativecommons.org/licenses/by-sa/3.0/. In accordance with CC-BY-SA, if you distribute this document or an adaptation of it, you must provide the URL for the original version.
Red Hat, as the licensor of this document, waives the right to enforce, and agrees not to assert, Section 4d of CC-BY-SA to the fullest extent permitted by applicable law.
Red Hat, Red Hat Enterprise Linux, the Shadowman logo, the Red Hat logo, JBoss, OpenShift, Fedora, the Infinity logo, and RHCE are trademarks of Red Hat, Inc., registered in the United States and other countries.
Linux® is the registered trademark of Linus Torvalds in the United States and other countries.
Java® is a registered trademark of Oracle and/or its affiliates.
XFS® is a trademark of Silicon Graphics International Corp. or its subsidiaries in the United States and/or other countries.
MySQL® is a registered trademark of MySQL AB in the United States, the European Union and other countries.
Node.js® is an official trademark of Joyent. Red Hat is not formally related to or endorsed by the official Joyent Node.js open source or commercial project.
The OpenStack® Word Mark and OpenStack logo are either registered trademarks/service marks or trademarks/service marks of the OpenStack Foundation, in the United States and other countries and are used with the OpenStack Foundation's permission. We are not affiliated with, endorsed or sponsored by the OpenStack Foundation, or the OpenStack community.
All other trademarks are the property of their respective owners.