Red Hat Training

A Red Hat training course is available for Red Hat Enterprise Linux

Chapter 64. Deprecated Adapters

The following adapters continue to be supported until the end of life of Red Hat Enterprise Linux 7 but will likely not be supported in future major releases of this product and are not recommended for new deployments. Other adapters from the mentioned drivers that are not listed here remain unchanged.
PCI IDs are in the format of vendor:device:subvendor:subdevice. If the subdevice or subvendor:subdevice entry is not listed, devices with any values of such missing entries have been deprecated.
To check the PCI IDs of the hardware on your system, run the lspci -nn command.
  • The following adapters from the aacraid driver have been deprecated:
    • PERC 2/Si (Iguana/PERC2Si), PCI ID 0x1028:0x0001:0x1028:0x0001
    • PERC 3/Di (Opal/PERC3Di), PCI ID 0x1028:0x0002:0x1028:0x0002
    • PERC 3/Si (SlimFast/PERC3Si), PCI ID 0x1028:0x0003:0x1028:0x0003
    • PERC 3/Di (Iguana FlipChip/PERC3DiF), PCI ID 0x1028:0x0004:0x1028:0x00d0
    • PERC 3/Di (Viper/PERC3DiV), PCI ID 0x1028:0x0002:0x1028:0x00d1
    • PERC 3/Di (Lexus/PERC3DiL), PCI ID 0x1028:0x0002:0x1028:0x00d9
    • PERC 3/Di (Jaguar/PERC3DiJ), PCI ID 0x1028:0x000a:0x1028:0x0106
    • PERC 3/Di (Dagger/PERC3DiD), PCI ID 0x1028:0x000a:0x1028:0x011b
    • PERC 3/Di (Boxster/PERC3DiB), PCI ID 0x1028:0x000a:0x1028:0x0121
    • catapult, PCI ID 0x9005:0x0283:0x9005:0x0283
    • tomcat, PCI ID 0x9005:0x0284:0x9005:0x0284
    • Adaptec 2120S (Crusader), PCI ID 0x9005:0x0285:0x9005:0x0286
    • Adaptec 2200S (Vulcan), PCI ID 0x9005:0x0285:0x9005:0x0285
    • Adaptec 2200S (Vulcan-2m), PCI ID 0x9005:0x0285:0x9005:0x0287
    • Legend S220 (Legend Crusader), PCI ID 0x9005:0x0285:0x17aa:0x0286
    • Legend S230 (Legend Vulcan), PCI ID 0x9005:0x0285:0x17aa:0x0287
    • Adaptec 3230S (Harrier), PCI ID 0x9005:0x0285:0x9005:0x0288
    • Adaptec 3240S (Tornado), PCI ID 0x9005:0x0285:0x9005:0x0289
    • ASR-2020ZCR SCSI PCI-X ZCR (Skyhawk), PCI ID 0x9005:0x0285:0x9005:0x028a
    • ASR-2025ZCR SCSI SO-DIMM PCI-X ZCR (Terminator), PCI ID 0x9005:0x0285:0x9005:0x028b
    • ASR-2230S + ASR-2230SLP PCI-X (Lancer), PCI ID 0x9005:0x0286:0x9005:0x028c
    • ASR-2130S (Lancer), PCI ID 0x9005:0x0286:0x9005:0x028d
    • AAR-2820SA (Intruder), PCI ID 0x9005:0x0286:0x9005:0x029b
    • AAR-2620SA (Intruder), PCI ID 0x9005:0x0286:0x9005:0x029c
    • AAR-2420SA (Intruder), PCI ID 0x9005:0x0286:0x9005:0x029d
    • ICP9024RO (Lancer), PCI ID 0x9005:0x0286:0x9005:0x029e
    • ICP9014RO (Lancer), PCI ID 0x9005:0x0286:0x9005:0x029f
    • ICP9047MA (Lancer), PCI ID 0x9005:0x0286:0x9005:0x02a0
    • ICP9087MA (Lancer), PCI ID 0x9005:0x0286:0x9005:0x02a1
    • ICP5445AU (Hurricane44), PCI ID 0x9005:0x0286:0x9005:0x02a3
    • ICP9085LI (Marauder-X), PCI ID 0x9005:0x0285:0x9005:0x02a4
    • ICP5085BR (Marauder-E), PCI ID 0x9005:0x0285:0x9005:0x02a5
    • ICP9067MA (Intruder-6), PCI ID 0x9005:0x0286:0x9005:0x02a6
    • Themisto Jupiter Platform, PCI ID 0x9005:0x0287:0x9005:0x0800
    • Themisto Jupiter Platform, PCI ID 0x9005:0x0200:0x9005:0x0200
    • Callisto Jupiter Platform, PCI ID 0x9005:0x0286:0x9005:0x0800
    • ASR-2020SA SATA PCI-X ZCR (Skyhawk), PCI ID 0x9005:0x0285:0x9005:0x028e
    • ASR-2025SA SATA SO-DIMM PCI-X ZCR (Terminator), PCI ID 0x9005:0x0285:0x9005:0x028f
    • AAR-2410SA PCI SATA 4ch (Jaguar II), PCI ID 0x9005:0x0285:0x9005:0x0290
    • CERC SATA RAID 2 PCI SATA 6ch (DellCorsair), PCI ID 0x9005:0x0285:0x9005:0x0291
    • AAR-2810SA PCI SATA 8ch (Corsair-8), PCI ID 0x9005:0x0285:0x9005:0x0292
    • AAR-21610SA PCI SATA 16ch (Corsair-16), PCI ID 0x9005:0x0285:0x9005:0x0293
    • ESD SO-DIMM PCI-X SATA ZCR (Prowler), PCI ID 0x9005:0x0285:0x9005:0x0294
    • AAR-2610SA PCI SATA 6ch, PCI ID 0x9005:0x0285:0x103C:0x3227
    • ASR-2240S (SabreExpress), PCI ID 0x9005:0x0285:0x9005:0x0296
    • ASR-4005, PCI ID 0x9005:0x0285:0x9005:0x0297
    • IBM 8i (AvonPark), PCI ID 0x9005:0x0285:0x1014:0x02F2
    • IBM 8i (AvonPark Lite), PCI ID 0x9005:0x0285:0x1014:0x0312
    • IBM 8k/8k-l8 (Aurora), PCI ID 0x9005:0x0286:0x1014:0x9580
    • IBM 8k/8k-l4 (Aurora Lite), PCI ID 0x9005:0x0286:0x1014:0x9540
    • ASR-4000 (BlackBird), PCI ID 0x9005:0x0285:0x9005:0x0298
    • ASR-4800SAS (Marauder-X), PCI ID 0x9005:0x0285:0x9005:0x0299
    • ASR-4805SAS (Marauder-E), PCI ID 0x9005:0x0285:0x9005:0x029a
    • ASR-3800 (Hurricane44), PCI ID 0x9005:0x0286:0x9005:0x02a2
    • Perc 320/DC, PCI ID 0x9005:0x0285:0x1028:0x0287
    • Adaptec 5400S (Mustang), PCI ID 0x1011:0x0046:0x9005:0x0365
    • Adaptec 5400S (Mustang), PCI ID 0x1011:0x0046:0x9005:0x0364
    • Dell PERC2/QC, PCI ID 0x1011:0x0046:0x9005:0x1364
    • HP NetRAID-4M, PCI ID 0x1011:0x0046:0x103c:0x10c2
    • Dell Catchall, PCI ID 0x9005:0x0285:0x1028
    • Legend Catchall, PCI ID 0x9005:0x0285:0x17aa
    • Adaptec Catch All, PCI ID 0x9005:0x0285
    • Adaptec Rocket Catch All, PCI ID 0x9005:0x0286
    • Adaptec NEMER/ARK Catch All, PCI ID 0x9005:0x0288
  • The following adapters from the mpt2sas driver have been deprecated:
    • SAS2004, PCI ID 0x1000:0x0070
    • SAS2008, PCI ID 0x1000:0x0072
    • SAS2108_1, PCI ID 0x1000:0x0074
    • SAS2108_2, PCI ID 0x1000:0x0076
    • SAS2108_3, PCI ID 0x1000:0x0077
    • SAS2116_1, PCI ID 0x1000:0x0064
    • SAS2116_2, PCI ID 0x1000:0x0065
    • SSS6200, PCI ID 0x1000:0x007E
  • The following adapters from the megaraid_sas driver have been deprecated:
    • Dell PERC5, PCI ID 0x1028:0x15
    • SAS1078R, PCI ID 0x1000:0x60
    • SAS1078DE, PCI ID 0x1000:0x7C
    • SAS1064R, PCI ID 0x1000:0x411
    • VERDE_ZCR, PCI ID 0x1000:0x413
    • SAS1078GEN2, PCI ID 0x1000:0x78
    • SAS0079GEN2, PCI ID 0x1000:0x79
    • SAS0073SKINNY, PCI ID 0x1000:0x73
    • SAS0071SKINNY, PCI ID 0x1000:0x71
  • The following adapters from the qla2xxx driver have been deprecated:
    • ISP24xx, PCI ID 0x1077:0x2422
    • ISP24xx, PCI ID 0x1077:0x2432
    • ISP2422, PCI ID 0x1077:0x5422
    • QLE220, PCI ID 0x1077:0x5432
    • QLE81xx, PCI ID 0x1077:0x8001
    • QLE10000, PCI ID 0x1077:0xF000
    • QLE84xx, PCI ID 0x1077:0x8044
    • QLE8000, PCI ID 0x1077:0x8432
    • QLE82xx, PCI ID 0x1077:0x8021
  • The following adapters from the qla4xxx driver have been deprecated:
    • QLOGIC_ISP8022, PCI ID 0x1077:0x8022
    • QLOGIC_ISP8324, PCI ID 0x1077:0x8032
    • QLOGIC_ISP8042, PCI ID 0x1077:0x8042
  • The following adapters from the be2iscsi driver have been deprecated:
    • BladeEngine 2 (BE2) Devices
      • BladeEngine2 10Gb iSCSI Initiator (generic), PCI ID 0x19a2:0x212
      • OneConnect OCe10101, OCm10101, OCe10102, OCm10102 BE2 adapter family, PCI ID 0x19a2:0x702
      • OCe10100 BE2 adapter family, PCI ID 0x19a2:0x703
    • BladeEngine 3 (BE3) Devices
      • OneConnect TOMCAT iSCSI, PCI ID 0x19a2:0x0712
      • BladeEngine3 iSCSI, PCI ID 0x19a2:0x0222
  • The following Ethernet adapters controlled by the be2net driver have been deprecated:
    • BladeEngine 2 (BE2) Devices
      • OneConnect TIGERSHARK NIC, PCI ID 0x19a2:0x0700
      • BladeEngine2 Network Adapter, PCI ID 0x19a2:0x0211
    • BladeEngine 3 (BE3) Devices
      • OneConnect TOMCAT NIC, PCI ID 0x19a2:0x0710
      • BladeEngine3 Network Adapter, PCI ID 0x19a2:0x0221
  • The following adapters from the lpfc driver have been deprecated:
    • BladeEngine 2 (BE2) Devices
      • OneConnect TIGERSHARK FCoE, PCI ID 0x19a2:0x0704
    • BladeEngine 3 (BE3) Devices
      • OneConnect TOMCAT FCoE, PCI ID 0x19a2:0x0714
    • Fibre Channel (FC) Devices
      • FIREFLY, PCI ID 0x10df:0x1ae5
      • PROTEUS_VF, PCI ID 0x10df:0xe100
      • BALIUS, PCI ID 0x10df:0xe131
      • PROTEUS_PF, PCI ID 0x10df:0xe180
      • RFLY, PCI ID 0x10df:0xf095
      • PFLY, PCI ID 0x10df:0xf098
      • LP101, PCI ID 0x10df:0xf0a1
      • TFLY, PCI ID 0x10df:0xf0a5
      • BSMB, PCI ID 0x10df:0xf0d1
      • BMID, PCI ID 0x10df:0xf0d5
      • ZSMB, PCI ID 0x10df:0xf0e1
      • ZMID, PCI ID 0x10df:0xf0e5
      • NEPTUNE, PCI ID 0x10df:0xf0f5
      • NEPTUNE_SCSP, PCI ID 0x10df:0xf0f6
      • NEPTUNE_DCSP, PCI ID 0x10df:0xf0f7
      • FALCON, PCI ID 0x10df:0xf180
      • SUPERFLY, PCI ID 0x10df:0xf700
      • DRAGONFLY, PCI ID 0x10df:0xf800
      • CENTAUR, PCI ID 0x10df:0xf900
      • PEGASUS, PCI ID 0x10df:0xf980
      • THOR, PCI ID 0x10df:0xfa00
      • VIPER, PCI ID 0x10df:0xfb00
      • LP10000S, PCI ID 0x10df:0xfc00
      • LP11000S, PCI ID 0x10df:0xfc10
      • LPE11000S, PCI ID 0x10df:0xfc20
      • PROTEUS_S, PCI ID 0x10df:0xfc50
      • HELIOS, PCI ID 0x10df:0xfd00
      • HELIOS_SCSP, PCI ID 0x10df:0xfd11
      • HELIOS_DCSP, PCI ID 0x10df:0xfd12
      • ZEPHYR, PCI ID 0x10df:0xfe00
      • HORNET, PCI ID 0x10df:0xfe05
      • ZEPHYR_SCSP, PCI ID 0x10df:0xfe11
      • ZEPHYR_DCSP, PCI ID 0x10df:0xfe12
    • Lancer FCoE CNA Devices
      • OCe15104-FM, PCI ID 0x10df:0xe260
      • OCe15102-FM, PCI ID 0x10df:0xe260
      • OCm15108-F-P, PCI ID 0x10df:0xe260